Basic format for control data
The transmission of control data from the computer
starts with a STX signal, followed by the command,
the parameters, and lastly an ETX signal in that order.
Add the parameter as required, in accordance with the
control detail.
STX
C1 C2 C3
Start
(02h)
3-character command
(3 bytes)
Command
Command
PON
POF
AVL
AMT
IMS
24
English
:
P1 P2 P3 P4
P5
Colon
Parameter(s)
Parameter
Control details
None
Power ON
None
Power OFF
***
Volume 000 - 100
0
Audio MUTE OFF
1
Audio MUTE ON
None
Input select (toggle)
HDMI 1 input
HM1
(HDMI1)
HDMI 2 input
HM2
(HDMI2)
DVI-D IN input
DV1
(DVI-D)
PC1
PC IN input (PC)
VIDEO input
VD1
(VIDEO)
COMPONENT input
YP1
(COMPONENT/
RGB IN)
UD1
USB input (USB)
Note
If multiple commands are transmitted, be sure to
wait for the response for the first command to come
from this unit before sending the next command.
When sending a command which does not require
parameter, a colon (:) is not needed.
If an incorrect command is sent by mistake, this
ETX
unit will send an "ER401" command back to the
computer.
End
In Standby condition (power OFF with remote control
(03h)
or <Power button (Unit)>), the unit responds to PON
command only.
When [Serial ID function] (see page 49) is set to
[On], only the command that matches the display ID
can be operated.
As the format, add the following header.
AD94;RAD=<XXX>;
For display ID, insert 001 to 100 or 000 for <XXX>.
For group ID, insert AAA (for A) to GGG (for G) for
<XXX>.
Consult your local Panasonic dealer for detail
instructions on command usage.
For more details, visit the following web site.
http://panasonic.net/prodisplays/