  • Page 2: Safety Precautions

    Copyright / Trademarks - This manual and its contents are copyrighted. - You may not copy this manual in whole or part, without written consent of Panasonic Industrial Devices SUNX Co., Ltd. - Windows is a registered trademark of Microsoft Corporation in the United States and other countries.
  • Page 3 Introduction Thank you for buying a Panasonic product. Before you use the product, please carefully read the installation instructions and the users manual, and understand their contents in detail to use the product properly. Types of Manual • There are different types of users manual for the GT707 series, as listed below. Please refer to a relevant manual for the unit and purpose of your use.
  • Page 4: Table Of Contents

    Table of Contents Table of Contents 1. System Configuration ............1-1 List of Models ..................1-2 1.1.1 GT Series Main Unit ................1-2 1.1.2 Options ....................1-2 Screen Creating Tool ................1-3 1.2.1 Tools Required for Screen Creation ............1-3 1.2.2 Software Usage Environment and Applicable Cables ......
  • Page 5 Table of Contents 3.2.4 Grounding ....................3-8 Wiring of COM Port ................3-9 3.3.1 Specifications of COM Port ..............3-9 3.3.2 Wiring Example of COM Port ..............3-10 Communication with PLC ..............3-12 3.4.1 Automatic Communication Settings Function ........3-12 3.4.2 Through Function ..................
  • Page 6: Before You Start

    Before You Start Before You Start  Usage conditions • Ambient temperatures: 0 to +50 °C • Ambient humidity should be 20 to 85% RH (at 25 °C) and non-condensing. • Usable alltitude: 2000 m above sea level or lower •...
  • Page 7 Before You Start  Touch switches • Always operate the touch switches with fingers. As the touch switches may be damaged due to the excessive load or shock (caused when being operated with any tools), the touch switches should be operated within the specified control force. Also, if the touch switches are pressed like kneading, the electrode may be worn out exceptionally, and cause the malfunction.
  • Page 8 Before You Start...
  • Page 9: System Configuration

    System Configuration...
  • Page 10: List Of Models

    COM port for connecting an 65536-color TFT color LCD external device (800x480 dots) RS-232C (D-sub 9-pin) GT707 24V DC Black AIG707WCL1G2 LED backlight Port for connecting tool software USB port (USB2.0 compliant) 1.1.2 Options  PLC connecting cables Item name Specifications Model No.
  • Page 11: Screen Creating Tool

    1.2 Screen Creating Tool 1.2 Screen Creating Tool 1.2.1 Tools Required for Screen Creation 1. Screen creation tool software This software is used for creating screens and making various settings. 2. Screen transfer cable (Cable for connecting a PC) A commercial USB cable is necessary. 1.2.2 Software Usage Environment and Applicable Cables ...
  • Page 12 System Configuration...
  • Page 13: Names And Functions Of Parts

    Names and Functions of Parts...
  • Page 14: Names And Functions Of Parts

    Names and Functions of Parts 2.1 Names and Functions of Parts 2.1.1 GT707  Names and functions of parts Name Function Various screens are displayed here. Switches can be operated and data entered ① Touch screen simply by touching the touch screen. A sheet is affixed to the touch panel to protect it from scrathes when shipping.
  • Page 15 2.1 Names and Functions of Parts 2.1.2 Operation Mode Setting Switches Reserved for Normal use Inhibit system Memory clear Mode system (Factory default) menu shift menu display (Usage prohibited) Switch setting  Operation when selecting the memory clear menu display •...
  • Page 16 Names and Functions of Parts...
  • Page 17: Installation And Wiring

    Installation and Wiring...
  • Page 18: Installation

    Installation and Wiring 3.1 Installation 3.1.1 Installation Environment When installing and using the GT series, always make sure the following conditions are observed.  Usage conditions • Ambient temperatures: 0 to +50 °C • Ambient humidity should be 20 to 85% RH (at 25 °C) and non-condensing. •...
  • Page 19: Restriction According To Mounting Directions

    3.1 Installation 3.1.2 Restriction According to Mounting Directions If the unit is used in a vertical orientation or installed in a horizontal orientation, note that the ambient usage temperature should be as below. Ambient Model name Condition temperature Horizontally installed GT707 0 to 50 °C Vertically used...
  • Page 20: Gt707 Installation Method

    Installation and Wiring 3.1.5 GT707 Installation Method Secure the GT to the installation panel using the fittings and screws (4 sets/per unit) provided with the unit. PROCEDURE 1. Place the GT unit in the installation panel. 2. Insert the fittings into the grooves of the GT unit, and slide them to be fixed. 3.
  • Page 21: Installing In Vertical Orientation

    3.1 Installation 3.1.6 Installing in Vertical Orientation • The GT series can be installed upright. The power supply connector is placed on the top side as illustrated below. • Select the vertical type when selecting a GT model in GTWIN.
  • Page 22: Wiring The Power Supply

    Installation and Wiring 3.2 Wiring the Power Supply 3.2.1 Precautions on Wiring • Perform wiring and placement of the cable so that there is no impression of external noise on the cable and no induction. • This product conforms to EN61131-2 for the European EMC Directive (EMC Directive 2004/108/EC).
  • Page 23: Wiring Of Terminal Block

    3.2 Wiring the Power Supply 3.2.3 Wiring of Terminal Block  Layout of terminal block for power supply Pin No. Function +24 V Functional ground  Suitable wires (strand wire) Nominal cross- Size Rated temperature Tightening torque sectional area AWG24 to 16 0.2 to 1.25 mm 75 °C or more 0.5 to 0.55 N・m...
  • Page 24: Grounding

    Installation and Wiring 3.2.4 Grounding Be sure to ground when the influence of noise is great The unit is tolerant against noise in normal environments, but if the environment is particularly susceptible to noise, please ground. Use dedicated grounding • Make the grounding point as close as possible to the GT and keep the distance of the grounding wire short.
  • Page 25: Wiring Of Com Port

    3.3 Wiring of COM Port 3.3 Wiring of COM Port 3.3.1 Specifications of COM Port  Specifications of GT707 COM port Pin No. Name Abbr. Signal direction N.C. - ― RS-232C Receive Data External devices to GT RS-232C Send Data GT to External devices N.C.
  • Page 26: Wiring Example Of Com Port

    Installation and Wiring 3.3.2 Wiring Example of COM Port  Wiring example (Between FP series COM port and GT707) • Use a loose wire for the connection on the PLC side. • It can be used in combination with our PLC equipped with a RS-232C interface. Applicable PLC models Model Usable combination...
  • Page 27 3.3 Wiring of COM Port  Wiring example (Between FP series PLC TOOL port and GT707) (1) • Use the mini-DIN 5-pin round connector for the connection on the FP-series PLC TOOL port side. The following figure shows the connection with the cable AFC8503/AFC8503S. •...
  • Page 28: Communication With Plc

    Installation and Wiring 3.4 Communication with PLC 3.4.1 Automatic Communication Settings Function  Overview of Automatic Communication Settings Function • After turning on the power supply, if there is not response from the PLC connected to the GT, the GT switches to the automatic setting mode for the communication conditions. •...
  • Page 29: Through Function

    PLC programs can be edited or monitored through the GT series. • The through function is always enabled when the PLC type for GT is set to Panasonic PLC. It can be used in combination with Panasonic PLC equipped with an interface.
  • Page 30: Battery For Clock

    Installation and Wiring 3.5 Battery for Clock 3.5.1 Battery for Clock • For using the clock function built-in the GT, a battery for the clock should be mounted. Even when the power supply is off, the clock works.  Battery for clock Item name Appearance Specifications...
  • Page 31: Lifetime And Time For Replacement Of Battery For Clock

    3.5 Battery for Clock 3.5.3 Lifetime and Time for Replacement of Battery for Clock  Lifetime of battery for clock Battery life, when operating at a normal temperature (25 °C), a normal humidity (65% RH), is as follows. GT model Life GT707 Approx.
  • Page 32 Installation and Wiring 3-16...
  • Page 33: Troubleshooting

    Troubleshooting...
  • Page 34: What To Do If An Error Occurs

    Troubleshooting 4.1 What to Do If an Error Occurs Problem Cause Solution Check the power within the specifications is Power is not on. supplied. Check the capacity of the power supply unit if it is The power voltage may be low. enough for the GT's power consumption.
  • Page 35 4.1 What to Do If an Error Occurs Problem Cause Solution No screen number has been written to the screen setting area Specify a correct screen number. (the first word in the basic communication area word device) from the PLC. Screen doesn't The screen number to which you switch.
  • Page 36 Troubleshooting Problem Cause Solution Bit F of the first word in the Buzzer sounds basic communication area bit continuously. device is set to ON. Refer to the baxic communication area map and The backlight flashing flag or check the operation of the bit allocated to PLC. Backlight color the backlight enable flag of the changes/flashes.
  • Page 37 4.1 What to Do If an Error Occurs  Operation security function Problem Cause Solution “Incorrect password.” Is displayed An unregistered Enter the registered password. on the login screen. password was entered. An incorrect password “Incorrect password.” Is displayed was entered in the Enter the registered password correctly.
  • Page 38 Troubleshooting  When using an SD memory card Data may be erased or the SD memory card may be damaged during the operation. Take measures for the situations as below. Problem Measures Transmitting GT configuration setting file using the logging function clears the information on the RAM.
  • Page 39: Error Codes And How To Handle Them

    4.2 Error Codes and How to Handle Them 4.2 Error Codes and How to Handle Them 4.2.1 About Error Codes • When an error occurs in the GT series, an error code displays at the top right of the screen. •...
  • Page 40 Troubleshooting Code No. Content Cause and solution SD memory card The SD memory card cannot be recognized. Check the SD memory **1006 recognition error card used. PLC model unmatch **1020 Check if the PLC program for transfer matches the destination PLC. error PLC model **1021...
  • Page 41: When Connected To A Fp Series Plc

    4.2 Error Codes and How to Handle Them 4.2.3 When Connected to a FP Series PLC Error codes which are sent from the PLC are listed in the table below. For details, refer to the table of MEWTOCOL-COM communication errors in PLC user's manuals.
  • Page 42: When Performing General-Purpose Serial Communication

    Troubleshooting 4.2.4 When Performing General-purpose Serial Communication  List of error codes Error code Error name Measures The value of BCC may be incorrect. Check if there is no calculation **0000 BCC error mistake. **0001 Format error A command format may be incorrect. Check if it is correct. A command used is not supported with the version of the GT.
  • Page 43: Specifications

    Specifications...
  • Page 44: Gt707 Specifications

    Specifications 5.1 GT707 Specifications 5.1.1 General Specifications Item Specifications Rated voltage 24V DC Operating voltage 21.6 to 26.4V DC range Power consumption 6 W or less (250 mA or less) Operating ambient 0 to +50 °C temperature Operating ambient 20 to 85% RH (at 25 °C), non-condensing humidity Storage ambient -20 to +60 °C...
  • Page 45: Performance Specifications

    5.1 GT707 Specifications 5.1.2 Performance Specifications Item Specifications Display device TFT color LCD Number of dots 800 (W) x 480 (H) dots Displayable area 153.8 (W) x 85.6 (H) mm Display (Note 1) Backlight LED backlight Can be adjusted on the menu screen, GTWIN configuration settings Backlight or PLC.
  • Page 46: Function Specifications

    Programs of Panasonic FP series PLCs can be uploaded/downloaded via SD memory cards. PLC backup/restore Programs and registers of a Panasonic FP series PLC connected to the COM port can function (Note 5) be backed up in the GT internal memory.
  • Page 47: Interface Specifications

    Item Specifications SD memory card, SDHC memory card Support media (Note 1) (The manufacturer name that the operation check has done: Panasonic Corporation) Conforms to SD standard. Supported format standard (Please format with a format software for SD memory cards.)
  • Page 48: Dimensions

    Specifications 5.2 Dimensions 5.2.1 GT707 Main Unit  Dimensions (Unit: mm)  Panel cutout dimensions (Unit: mm)
  • Page 49: For Connecting Plc (Afc8503/Afc8503S)

    5.2 Dimensions 5.2.2 For Connecting PLC (AFC8503/AFC8503S) This is the cable used for connecting the GT707 to the tool port of Panasonic PLC, FP0R/FP-...
  • Page 50 Specifications...
  • Page 51 Record of changes Manual No. Date Record of Changes WUME-GT707H-01 Aug.2015 1st Edition...