Using The Focus Recall Function - Yamaha QL5 Reference Manual

Hide thumbs Also See for QL5:
Table of Contents

Advertisement

• RACK tab
Enables you to choose from GEQ RACK, EFFECT RACK, or PREMIUM RACK. You can
individually select an GEQ for a Flex15GEQ or an effect used in dual mode.
• PATCH/OTHERs tab
You can select the following parameters.
INPUT PATCH
All input channel patches, insert in/out patches, Direct Out patches
OUTPUT PATCH
All output channel patches, insert in/out patches
INPUT NAME
Channel names, icons, and colors for all input channels
OUTPUT NAME
Channel names, icons, and colors for all output channels
Analog gain, phantom power on/off status, Gain Compensation, phase
HA
settings
CH LINK
Channel link settings
MUTE GROUP
Setting a MUTE group name
NAME
CUSTOM FADER
Custom fader bank settings
*1
BANK
*1. While in PREVIEW mode, changes that are made in QL Editor are not applied immediately. They are applied
after PREVIEW mode is exited.
• DCA tab
You can select ALL, LEVEL/ON, or NAME. If ALL is selected, all channel parameters will
be copied. If LEVEL/ON is selected, the master level and DCA channel on/off status will
be copied. If NAME is selected, the DCA group name will be copied. You can select the
copy-source channels individually for each DCA group 1-16.
For DCA, although you can turn on both the LEVEL/ON button and the NAME button,
they will then both be switched off if you turn on the ALL button.

Using the Focus Recall function

"Focus Recall" is a function that lets you specify the scene parameters that will be recalled
(loaded) when you recall a scene. You can specify these settings for each scene. This function
is useful if you want to recall only the input channel settings of a specific scene.
NOTE
In contrast to Focus, the QL series console also features a "Recall Safe" function that enables
you to exclude specific channels and parameters from recall operations. However, while the
Focus Recall function is specified individually for each scene, the Recall Safe settings are applied
to all scenes.
STEP
1. Press the SCENE field in the Function Access Area.
2. Press the FOCUS tab at the bottom of the SCENE LIST window.
3. In the SCENE LIST window, press the SET button for the scene you want to set.
4. Follow the procedure starting with step 3 in the
page 66
to make settings.
5. Recall a scene for which you have made Focus Recall settings.
SCENE field
NOTE
• The FOCUS field enables you to make settings for the Focus function. The buttons in this field
correspond to the scene list shown on the left side of the SCENE LIST window.
• Scenes for which Focus settings are made are indicated by a "FOCUS" indication in the STATUS
field of the SCENE LIST window.
• You can use the Focus function in conjunction with the Recall Safe function. Channels or
parameters that are excluded from Recall operations by either Focus or Recall Safe will not be
recalled.
• For FOCUS RECALL, the NAME parameter is included in the DCA indicator.
88
"Using the Recall Safe
function" on
SCENE LIST window
Scene memory
Reference Manual

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Ql1Ql series