Console Lock - Yamaha QL5 Reference Manual

Hide thumbs Also See for QL5:
Table of Contents

Advertisement

Custom fader bank settings for individual scenes
Custom fader bank settings can be stored/recalled for individual scenes. For details, refer to
"Using the Focus Recall
function" on
page
Custom fader bank settings
QL5
Recall
QL5 console
NOTE
• Custom fader bank settings differ between models, and are not compatible. For example, scenes
stored by the QL5 cannot be recalled on the QL1.
• In addition, the user level affects storing/recalling of custom fader bank settings. For example, if
you are logged-in as a user or Guest, you cannot recall settings stored by the Administrator.
Precautions for when Loading Console Data
Custom fader bank settings are not only included in user settings, but in scene data as well.
The custom fader bank settings that are called up vary depending on the logged-in user, the
type of the loaded data, and the version. Please note the following points:
• If you load console data of the ALL type as Administrator, the custom fader bank settings
for the saved Administrator are called up.
If you load ALL data as Guest or another user, the custom fader bank settings for the saved
current scene are called up.
• If you load ALL data that was saved in CL V1.70 or earlier, since scenes do not include
custom fader bank settings, the custom fader bank settings for the current scene when the
load was performed are applied to all scenes. Therefore, before loading ALL data, we
recommend that you either change users to set the custom fader bank to the desired
setting, or that you enable Recall Safe for the custom fader bank.
88.
QL1
Store
Recall
Store
QL1 console

Console Lock

You can temporarily prohibit console operations in order to prevent unwanted operation. This
setting disables operations of the panel, so that controllers cannot be operated by an
accidental touch or by an unauthorized third party while the operator is taking a break.
If a password is set for the currently logged-in user, that password will be used for the Console
Lock function. When the Console Lock function is enabled, the CONSOLE LOCK screen will
appear and all controllers will become inoperable.
NOTE
• If you have forgotten the password, refer to
page
237.
• The Guest cannot set a password.
• Even while the console is locked, you can operate the console from an external device via MIDI
or QL Editor as usual.
203
"Initializing the unit to factory default
settings" on
Reference Manual
Setup

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Ql1Ql series

Table of Contents