Yamaha QL5 Reference Manual page 153

Hide thumbs Also See for QL5:
Table of Contents

Advertisement

 RMio64-D display
Displays the RMio64-D panel. You can press the buttons to change settings.
1
2
3
4
6
7
1
MADI SRC ON indicator
MADI SRC ON button
Switches the SRC (Sampling Rate Converter) on and off.
2
MADI SRC WCLK IN indicator
MADI SRC WCLK IN button
Use this button to select whether to use (indicator on) or not use (indicator off) the word
clock input from the MADI WCLK IN FOR SRC jack on the rear panel of the RMio64-D
as a standard clock for SRC.
3
MADI INPUT RATE Fs 44.1kHz indicator
MADI INPUT RATE Fs 48kHz indicator
Automatically detect and indicate whether the MADI input signal is 44.1 kHz or 48 kHz.
Both indicators remain off if there is no valid MADI input signal.
4
MADI INPUT RATE 1Fs indicator
MADI INPUT RATE 2Fs indicator
MADI INPUT RATE 4Fs indicator
MADI INPUT RATE 1Fs/2Fs/4Fs button
Select either 1Fs (1x), 2Fs (2x), or 4Fs (4x), based on the MADI input frequency. For
example, if the MADI input signal is 192 kHz (4x 48 kHz), confirm that the MADI INPUT
RATE Fs 48kHz indicator is on and then select "4Fs".
NOTE
When "2Fs" is selected, the unit automatically detects the frame frequency (48 kHz/96 kHz) of
the MADI input signal.
5
9
8
5
MADI STATUS INPUT status
MADI STATUS OUTPUT status
Display information regarding the MADI input and output signals (frame frequency/
number of channels).
6
WORD CLOCK WCLK IN indicator
WORD CLOCK MADI indicator
WORD CLOCK DANTE indicator
WORD CLOCK WCLK IN/MADI/DANTE buttons
Used to select the word clock source.
Uses the word clock signal being input from the WORD CLOCK IN connector on
WCLK IN
the rear panel of RMio64-D. The indicators flash when there is no valid word clock
input.
Uses the word clock of the MADI input signal. The indicators flash when there is no
MADI
valid word clock input.
DANTE
Uses the word clock of the Dante network.
7
WORD CLOCK Fs indicator
Indicates the word clock frequency at which the unit is operating. Flashes when not
synchronized.
8
EXTERNAL CONTROL indicator
This indicator comes on when there is a valid parameter that can be operated only
externally by remote control.
Refer to "Remote Control" in the RMio64-D Owner's Manual for details about
parameters that can be operated by remote control.
9
OUTPUT PATCH button
Press this button to access the OUTPUT PATCH window, where you can make output
port settings for RMio64-D.
153
I/O devices and external head amps
Reference Manual