Function
CH JOB
Access Area
menu
NOTE
After initialization, the TARGET CHs field will be empty (nothing is selected).
CH DEFAULT MODE window
Enables you to initialize parameters.
1
3
1
TARGET CHs field
Indicates the channel selected for initialization. While this window is displayed, press a
[SEL] key on the top panel to select an input channel (multiple selection is allowed). The
field will indicate the selected channel(s). Press the same [SEL] key once again to
de-select the channel.
NOTE
• If you press this field while a channel is selected, all selected channels will be de-selected.
• In the case of the QL1, faders that do not exist on the model will not be shown.
2
DEFAULT button
After selecting the channel, press this button to execute the initialization operation.
3
CLOSE button
Press this button to close the window and return to the previous screen.

About Mix Minus

The Mix Minus function removes a specific channel signal from the signals sent to the MIX/
MATRIX buses. You can use this function to quickly send monitoring signals to a performer or
announcer simply by removing his or her audio signal.
NOTE
This Mix Minus function is a shortcut for settings, rather than an operation to switch between
modes. Therefore, even after using this function, you can still edit any parameter on the window
without restrictions.
STEP
1. Hold the [SEL] key while pressing the MIX/MATRIX bus key in the SELECTED
CHANNEL section.
2. The MIX MINUS popup window will open.
3. If you wish to remove an additional input channel, press the corresponding [SEL]
key.
4. If necessary, in the DESTINATION field, select a bus.
You cannot select a FIXED bus.
5. Press the OK button to set the parameters as follows:
• The send level of the signals sent from the selected input channels is lowered to-∞dB.
• The send level of the signals sent from all other input channels is set to nominal
(0.0dB).
• Send to the destination bus is turned on, and the send point is switched to POST.
• For the stereo input channels, the send level of the signal sent from both channels is
set to -∞ dB.