This part belongs to the feature Core in SUSI APIs.
-
Select or clear the check box to select the information to get or set in its text
box.
-
In Boot Counter
-
To enable the Bootcounter write 'true' and click set To disable the Bootcounter
write 'false' and click set
-
To reset the BootTimes parameter to 0, just type 0 in the BootTimes text box
with its check box selected, and then click the "Set" button.
-
In Run Timer
-
Set the Running text box to 1 to start the timer, or 0 to stop the timer.
-
Set the Autorun text box to 1 to start the timer when the system restarts.
II. Watchdog
When the SusiDemo program executes, it shows watchdog information in the "Time-
out Information" fields - "Min", "Max", and "Step" in milliseconds. For example, for a
range of 1 ~ 255 seconds, 1000 appears in the "Min" text box, 255000 appears in the
"Max" text box, and 1000 appears in the "Step" text box.
Here is an example of how to use the watchdog timer:
-
Type 3000 (3 sec.) in the "Timeout" text box and optionally type 2000 (2 sec.) in
the "Delay" text box. Click the "Start" button. The "Left" text box will show the
approximate countdown value the watchdog timer. (This is a software timer in
the demo program, not the actual watchdog hardware timer so it is not very
accurate.)
-
Before the timer counts down to zero, you may reset the timer by clicking the
"Refresh" button, stop it by clicking the "Stop" button.