Outdoor Unit / RK(X)H-C, ARK(X)H-C, R(Y)N-C

3. Outdoor Unit / RK(X)H-C, ARK(X)H-C, R(Y)N-C

3.1

Removal of External Panels

Procedure
Step
1
The stop valve cover
can be removed when
the fixing screw is
removed.
190
Warning
Be sure to wait 10 minutes or more after turning off all power supplies
before disassembling work.
Procedure
Stop valve
cover
(R4026)
Stop valve
(liquid)
Stop valve (gas)
SiENBE04-401A
Points
As hooks are provided, slide
the cover downward to
remove.
The forced cooling operation
in the pumping down mode
can be carried out by
pushing the ON / OFF button
on the indoor unit for 5
seconds.
Removal Procedure