Control Specification

3. Control Specification

3.1

Mode Hierarchy

There are two modes; the mode selected in user's place (normal air conditioning mode) and
Outline
forced operation mode for installation and providing service.
1. For heat pump model
Detail
2. For cooling only model
Unless specified otherwise, an indoor dry operation command must be regarded as cooling
Note:
operation.
58
There are following modes; stop, cooling (includes drying), heating (include defrosting)
Air conditioner control mode
Forced operating mode
Forced cooling (for Pump Down Operation)
Normal operating mode
Cooling
Heating
Defrosting
Stop mode (except for cooling/heating modes by indoor command)
Preheat operation
During C (capacitor) is discharging
Stop
There are following models; stop and cooling (including drying).
Air conditioner control mode
Forced operating mode
Normal operating mode
Forced cooling (for Pump Down Operation)
Cooling
Stop mode (except for cooling modes by indoor command)
Preheat operation
During C (capacitor) is discharging
Stop
SiENBE04-401A
(R2829)
(R2830)