Daikin FTKS20CVMB Service Manual page 222

Inverter pair wall mounted type
Hide thumbs Also See for FTKS20CVMB:
Table of Contents

Advertisement

SiENBE04-401A
Step
Removal Procedure
Procedure
Outdoor Unit / RK(X)H-C, ARK(X)H-C, R(Y)N-C
In case that the removal seems
to be hard;
1. Remove the piping
connection part (brazing
part) which is easy to
remove and restore.
2. Cut the pipes on the main
unit by a miniature copper
tube cutter in order to make
it easy to remove.
NOTE:
Don't use a metal saw for
cutting pipes by all means
because the chips come into the
circuit.
(R4075)
Cautions at the restoration.
Wrap the motor valve with wet
cloth and make up water so that
the cloth will not be dried and
avoid excessive heating.
Caution
Be careful about four way
valve, pipes and so on, which
were heated up by a gas
brazing machine, so as not to
get burnt on your hands.
(R4076)
Points
213

Hide quick links:

Advertisement

Table of Contents

Troubleshooting

loading

Table of Contents