2.3

Removal of Reactor and Partition Plate

Procedure
Step
Remove the outer panels.
Remove the electrical
box.
1. Remove the reactor.
1
Loosen the screw.
Lift and remove the
reactor.
2. Remove the partition
plate.
1
Loosen the 2 screws.
Removal Procedure
Warning
Be sure to wait 10 minutes or more after turning off all power supplies
before disassembling work.
Procedure
Outdoor Unit / RK(X)S-C, ARK(X)S-C
Reactor
Partition plate