List Of Functions; High Grade Models - Daikin FTKS20CVMB Service Manual

Inverter pair wall mounted type
Hide thumbs Also See for FTKS20CVMB:
Table of Contents

Advertisement

List of Functions

1. List of Functions

1.1

High Grade Models

Category
Functions
Inverter (with Inverter Power Control)
Operation Limit for Cooling (°CDB)
Basic
Function
Operation Limit for Heating (°CWB)
PAM Control
Oval Scroll Compressor
Swing Compressor
Compressor
Rotary Compressor
Reluctance DC Motor
Power-Airflow Flap
Power-Airflow Dual Flaps
Power-Airflow Diffuser
Wide-Angle Louvers
Comfortable
Vertical Auto-Swing (Up and Down)
Airflow
Horizontal Auto-Swing (Right and Left)
3-D Airflow
Comfort Airflow Mode
3-Step Airflow (H/P Only)
Auto Fan Speed
Indoor Unit Silent Operation
Night Quiet Mode (Automatic)
Outdoor Unit Silent Operation (Manual)
Comfort
Control
Intelligent Eye
Quick Warming Function
Hot-Start Function
Automatic Defrosting
Automatic Operation
Operation
Programme Dry Function
Fan Only
New Powerful Operation (Non-Inverter)
Inverter Powerful Operation
Priority-Room Setting
Cooling / Heating Mode Lock
Lifestyle
Home Leave Operation
Convenience
Indoor Unit On/Off Switch
Signal Reception Indicator
Temperature Display
Another Room Operation
: Holding Functions
Note:
— : No Functions
2
Category
–10
–10
H
1
~46
~46
–15
~20
Health &
Clean
Timer
Worry Free
"Reliability &
Durability"
Flexibility
Remote
Control
Remote
control
H
H
Functions
Air Purifying Filter with Bacteriostatic,
Virustatic Functions
Photocatalytic Deodorizing Filter
Air Purifying Filter with Photocatalytic
Deodorizing Function
Titanium Apatite Photocatalytic
Air-Purifying Filter
Mold Proof Air Filter
Wipe-clean Flat Panel
Washable Grille
Filter Cleaning Indicator
Good-Sleep Cooling Operation
24-Hour On/Off Timer
Night Set Mode
Auto-Restart (after Power Failure)
Self-Diagnosis (Digital, LED) Display
Wiring Error Check
Anticorrosion Treatment of Outdoor
Heat Exchanger
Multi-Split / Split Type Compatible
Indoor Unit
Flexible Voltage Correspondence
High Ceiling Application
Chargeless
Either Side Drain (Right or Left)
Power Selection
5-Rooms Centralized Controller
(Option)
Remote Control Adapter
(Normal Open-Pulse Contact) (Option)
Remote Control Adapter
(Normal Open Contact) (Option)
DIII-NET Compatible (Adapter)
(Option)
Wireless
Wired
1 :
Lower limit can be extended to –15°C by cutting
jumper. (facility use only)
2 :
Digital Only
SiENBE04-401A
2
2
H
H
10m
10m
List of Functions

Hide quick links:

Advertisement

Table of Contents

Troubleshooting

loading

Table of Contents