Outdoor Unit / RK(X)S-C, ARK(X)S-C
2. Outdoor Unit / RK(X)S-C, ARK(X)S-C
2.1
Removal of Panels and Fan Motor
Procedure
Step
1. Features
1
Loosen the screw of the
stop valve cover.
Pull down the stop
valve cover and remove
it.
170
Warning
Be sure to wait 10 minutes or more after turning off all power supplies
before disassembling work.
Procedure
Outdoor air
thermistor
Handle
Stop
valve
cover
Shelter
Hooks
SiENBE04-401A
Points
Take care not to cut your
finger by the fins of the heat
exchanger.
The stop valve cover is
united with the shelter.
When reassembling, make
sure to fit the 5 hooks.
Removal Procedure