REMEHA Quinta Pro series Installation, User And Service Manual page 26

Wall-hung gas condensing boilers
Hide thumbs Also See for Quinta Pro series:
Table of Contents

Advertisement

6 Installation
Fig.14
Room-sealed version (concentric)
Fig.15
Different pressure areas
L
=
26
With a closed version, both the flue gas outlet and the air supply openings
are connected (concentrically).
L
=
Tab.12 Maximum chimney length (L)
AD-0000029-01
A 100/100 mm flue gas adapter (accessory) must be fitted for this connec­
tion.
Combustion air supply and flue gas discharge are possible in different
pressure areas and semi-CLV systems, with the exception of the coastal
area. The maximum permitted height difference between the combustion
air supply and the flue gas outlet is 36 m.
+
Tab.13 Maximum chimney length (L) in the various pressure zones
AD-0000030-01
Tab.14 Pipe reduction for each element used (parallel)
Room-sealed version (C13, C33, C43, C63, C93)
Flue gas outlet connection
Air supply connection
Quinta Pro
30
45
65
90
115
Connection in different pressure areas (C53, C83)
Flue gas outlet connection
Air supply connection
Quinta Pro
80 mm
30
20 m
45
20 m
65
-
90
-
115
-
Reduction table
Diameter
45° bend
60 mm
0.9 m
70 mm
1.1 m
80 mm
1.2 m
90 mm
1.3 m
100 mm
1.4 m
110 mm
1.5 m
130 mm
1.6 m
Diameter
80–125 mm
100–150 mm
20 m
20 m
16 m
20 m
-
13 m
-
13 m
-
7 m
Diameter
90 mm
100 mm
110 mm
36 m
36 m
36 m
36 m
36 m
36 m
2 m
8 m
34 m
-
4 m
32 m
-
-
24 m
Pipe reduction
90° bend
3.1 m
3.5 m
4.0 m
4.5 m
4.9 m
5.4 m
6.2 m
123157 - v.06 - 24022015
130 mm
36 m
36 m
36 m
36 m
36 m