B
Second MNT +1 Page Format
Installed Equipment
Fuel Mgt Sys: Y
Fuel Mgt Ind: N
Full Fuel: 0064
The third MNT+1 page has the following selection choices and format.
1.Whether the KLN 94 is installed with an air data computer.
2.Whether the KLN 94 is installed with a back-up emergency battery (not available from
Honeywell).
3.Below what aircraft bus voltage should the back-up battery be used. (Not a choice if there is no
emergency battery).
Third MNT +1 Page Format
Installed Equipment
232 Air Data: Y
Emerg Bat: Y
Use Bat: 10.2 V

2.4.1.2 Maintenance 2 (MNT 2) Page

The MNT 2 page displays total hours of operation and number of power cycles on the KLN 94
and is not configurable.

2.4.1.3 Maintenance 3 (MNT 3) Page

The MNT 3 page is used to calibrate the OBS setting of the aircraft's HSI or CDI to the KLN 94 so
that the KLN 94 reads the value the pilot selects on the HSI or CDI. It is necessary to configure
this page only if the KLN 94 is interfaced to an HSI or CDI resolver such that the KLN 94 is able
to read the course selected on the HSI or CDI. To calibrate the OBS:
1.Select a course using the course select/OBS knob on the HSI or OBS that is interfaced with the
KLN 94. It is suggested that a course increment of 10 degrees (example 10,150, 270, etc.) be
used so that the course can be selected as precisely as possible.
Rev. 4, Jan/2003
Selection Choices
Y or N for yes or no
Y or N
(this line blank if N is selected above)
0000 to 9999
(this line blank if no fuel mgt sys or if fuel
mgt sys has its own control/indicator)
Selection Choices
Y or N for yes or no
Y or N for yes or no
0-33 V (this line blank if no emerg bat)
10599I04.CDL
KLN 94
Default
N
N
0000
Default
N
N
10.2 V
Page 2-69