Data Protocol; Rs232 Output Data Item Definitions - BENDIXKing KLN 94 Installation Manual

Table of Contents

Advertisement

B

Data Protocol

Data shall be sent in blocks having the following format:
<STX><id><dddd><it><id><dddd><it>...<id><dddd><it><ETX>
<STX>
<id>
<dddd>
<it>
<CR>
<STX>
<STX>
<id>
<dddd>
<it>
<CR>
<STX>
Any data which is invalid or exceeds the data format will be filled with dashes.

RS232 OUTPUT DATA ITEM DEFINITIONS

There are two RS232 output data item definitions, as represented in the following tables. The first table
shows the Standard definitions, as selected on the MNT7 page (see
Item
Data
Designator
Format
A
s dd mmhh
Rev. 4, Jan/2003
ASCII start of text character
item designator
item data
item terminator
ASCII carriage return character
ASCII end of text character
ASCII end of text character
item designator
item data
item terminator
ASCII carriage return character
ASCII end of text character
STANDARD RS232
Data Field
Width
9
present latitude; dash if position flag is set.
s=sign: N for North, S for South
dd=degrees
mm=minutes
hh=hundreths of minutes
10599I04.CDL
paragraph 2.4.1.7
in this manual).
Description
KLN 94
Page A-11

Hide quick links:

Advertisement

Table of Contents
loading