140
2.10
2.9
2.8
2.7
2.6
2.5
VX8 Reference Guide
what is going on in WLinq (input data, string
replacements, data editing format, key
simulations etc.)
WLinq Settings Exporter, a small tool with which
you easily can export WLinq's settings to a text
file. Makes support easier.
Changed the key translation table so it can be
customized also when used with Citrix clients.
Minor changes:
When using the edit box Scan Code Tester the
value is automatically put into the edit box Key
Code.
There is now an alias for the Delay function in the
data output format. It is called Sleep.
Added the Duplicate String Filter function.
Added an alternative way for WLinq to send data to an
application.
On the property page Keyboard it was possible to get
two identical error messages if you entered an invalid
value in the edit box Inter-character Delay. Fixed.
On startup, WLinq erroneously sent a linefeed character
(ASCII 10) out on the serial port despite that
Initialization String was empty. Certain barcode readers
interpret this as garbage data and can't interpret the
command correctly.
The function Hide window on incoming data did not
work. This error was caused by changes in version 2.5.
Added a lite version. In the lite version all data editing
functions has been removed.
The qualifier keys Shift, Control and Alt did not work in
Windows 9x/ME. This had the effect that characters
that needed any of the qualifiers did not work. This
fault is present in version 2.5 and 2.6.
Another problem was found and corrected. It had to do
with the Caps Lock keyboard indicator. This was also a
problem only in Windows 9x/ME.
The process of reading the settings from the registry
has been made a lot stricter and when errors occur
very specific error messages are displayed. Hopefully
this will ease troubleshooting and support.
Added the topic
Frequently Asked
Added the functions Reboot() and RebootForced() in
the
output data
format.
Added password protection so that users can't change
the settings or exit WLinq.
Added the possibility to specify a timeout as a data
string terminator.
Added <tab> as an alias to <ht>.
Added control of the signals DTR and RTS.
Added control of the extended status per key to enable
to send a normal Enter and Enter on the
keypad
.
A very small memory leak was fixed.
A cosmetic improvement in the dialog box Lock Output
Window.
2002-06-17
2002-04-03
2001-11-20
2001-10-19
Question.
2001-09-10
2001-08-08
numeric
FreeFloat WLinq
E-EQ-VX8RG-A