Cleaning Ice Making System - Sub-Zero 315I Technical Service And Parts Manual

Table of Contents

Advertisement

Model 315I (UC Ice Maker)
Cleaning the Ice Making System
Though the water system flushes away mineral impurities during the harvest cycle, some impurities will inevitably
remain, sticking to parts of the ice machine, causing malformed ice cubes. This build up of mineral scale can short-
en the life of the unit.
To keep the ice machine operating properly, these impurities or minerals will have to be dissolved regularly with ice
machine cleaner. (Sub-Zero part #19034306)
THE ICE MACHINE CLEANER SOLD BY SUB-ZERO
CONTAINS ACIDS WHICH MAY CAUSE BURNS.
ALWAYS WEAR HEAVY RUBBER GLOVES AND
EYE PROTECTION WHEN WORKING WITH ICE
MACHINE CLEANER.
IF ICE MACHINE CLEANER CONTACTS SKIN,
FLUSH WITH WATER.
IF ICE MACHINE CLEANER CONTACTS EYES,
FLUSH WITH LARGE AMOUNTS OF WATER AND
CONTACT PHYSICIAN IMMEDIATELY.
IF SWALLOWED, DO NOT INDUCE VOMITING.
DRINK LARGE AMOUNTS OF WATER OR MILK.
CALL PHYSICIAN IMMEDIATELY.
KEEP ICE MACHINE CLEANER OUT OF REACH
OF CHILDREN.
To clean the ice making system, follow the instructions
below:
1. Turn ice machine
control knob to
OFF.
(See Figure 4-3)
Figure 4-3. Control Turned OFF
2. Scoop all ice out of
storage bin and either
discard it or save it in
an ice chest or cooler.
(See Figure 4-4)
Figure 4-4. Empty Bin
Maintenance & Cleaning
3. Pour four ounces
of Ice Machine
Cleaner (part
#19034306) into
ice maker water
reservoir.
(See Figure 4-5)
4. Turn ice machine
control knob to
ON and allow to
run for approxi-
mately two hours
(four ice making
cycles).
(See Figure 4-6)
5. Turn ice machine
control knob to
OFF, then pour
hot (95°/35°C -
115°F/46°C)
water into ice
storage bin to
melt ice that has
been produced.
(See Figure 4-7)
6. Clean bin liner of mineral scale by mixing a small
amount of ice machine cleaner with hot water.
Using a clean soft cloth, wipe down bin liner with
this solution, then rinse with clean hot water.
7. Clean/sanitize ice storage bin as described earlier.
8. Turn ice machine control knob to ON and replace
ice removed in step 2.
4-3
#3757320 - Revision B - August, 2005
Figure 4-5.
Pour Cleaner into Reservoir
Figure 4-6. Control Turned ON
for Two Hours
115°
95°
Figure 4-7.
Pour Hot Water into Bin