Model 315I (UC Ice Maker)
Initial Start-Up
When the installation is complete and all electrical and
water hook-ups have been checked, be sure to remove
all tape and packing materials before initial start-up.
Follow the instructions below for initial start-up:
1. Pull the control knob from the ice machine control
shaft. (See Figure 2-12)
2. Remove the control face plate by pulling the top for-
ward to disengage the velcro strips, then lift up.
(See Figure 2-12)
3. Remove the inner control access panel by extract-
ing the three screws, then lower the panel slightly
and pull forward. (See Figure 2-12)
4. Locate the cycle timer and rotate the shaft clock-
wise until the cam is in the harvest cycle position
(switch button out). (See Figure 2-13)
5. Turn the water supply ON.
6. Make sure there is power to the unit, then place the
ice machine control knob on the control shaft and
turn the ice machine control knob to the "NORMAL"
position (pointing straight down). (See Figure 2-14)
7. Allow the unit to run for approximately one hour,
then check the size of the ice cubes.
NOTE: To confirm proper cube size, see "Cube Size
Control Adjustment" in the Maintenance, Cleaning &
Adjustment section of this manual. If cube size is incor-
rect, follow the Cube Size Control Adjustment proce-
dures on that page.
8. After adjusting the cube size control and/or confirm-
ing cubes are the correct size, replace the inner
control access panel, the control face plate and the
control knob.
Installation Information
Inner Control
Access Panel
Remove Control Knob, Face Plate & Access Panel
Figure 2-13. Rotate Timer Cam to Harvest Position
Control Knob
Figure 2-14. Control Knob in "NORMAL" Position