Declaration Of Performance - Contura C i40 Installation Instructions Manual

Hide thumbs Also See for C i40:
Table of Contents

Advertisement

GB
82
CERTIFICATE

DECLARATION OF PERFORMANCE

No. Ci40-CPR-130912-SE-1
PRODUCT
Product type
Type designation
Manufacturing number
Intended area of use
Fuel
MANUFACTURER
Name
Address
CHECKS
According to AVCP
European standard
Test institute
DECLARED PERFORMANCE
Essential characteristics
Reaction to fire
Minimum distance to combustible material
Risk of falling embers
Emissions from combustion
Surface temperatures
Cleaning options
Mechanical durability
Emissions of hazardous substances
Nominal output
Efficiency
Flue gas temperature in connector at nominal
output
The undersigned is responsible for the manufacture and conformity with the declared performance.
Niklas Gunnarsson,
Markaryd, September 12, 2013
Insert lit with solid biofuels
Contura i40
See rating plate on the insert
Heating of rooms in residential buildings
Wood
NIBE AB / Contura
Box 134, Skulptörvägen 10
SE-285 23 Markaryd, Sweden
System 3
EN 13229:2001/AC:2006, EN-13229:2001/A2:2004/AC:2007
Rein-Ruhr Feuerstätten Prüfstelle, NB 1625,
has checked declared performance and issued test report no. RRF-29 13 3402
Performance
A1 WT
150 mm to rear
150 mm to side
According to the given conditions in the installa-
tion instructions.
Approved
CO
NOx
OGC
PM
Approved
Approved
Approved
Approved
7 kW
81%
328°C
Business area manager NIBE STOVES
0.07%
91 mg/m
3
59 mg/m
3
17 mg/m
3
Harmonised technical
specification
EN 13229:2001/AC:2006,
EN-13229:2001/A2:2004/AC:2007