SETuP-function
upslope current
dependency (*C)
Downslope current
dependency (*C)
TIg Antifreeze (*C)
mmA Antifreeze (*C)
vRd (*C)
2T downslope cut off
Tacking automatics
Limitation of rate of current
rise with high currents
mmA/TIg method selection
with remote control (C*)
SearchArc On/Off
Current freeze function
memory channel selection
with Up/Down buttons (C*)
Activation of the Plus/minus
buttons (C*)
Water cooler flow guard (C*) A17 on
Water cooler automatic
control (C*)
Water cooler temperature
guard (C*)
Automatic remote control
device recognition (C*)
Tail arc
© keMppi oy
*C = Common: applies to all memory
display
channels
Factory setting with a grey background
A1
on
the upslope time is determined by the current.
off
the upslope time remains as set.
A2
on
the downslope time is determined by the
current (the user may set the slope gradient).
off
the downslope time remains as set.
A3
on
tig antifreeze on.
off
tig antifreeze off.
A4
on
mma antifreeze on.
off
mma antifreeze off.
A7
on
vrd mode: idle voltage < 35 v
off
normal idle voltage
A8
on
in 2t mode, cut off the downslope with a quick
push of the start button.
off
Quick push has no effect.
A9
on
if welding has lasted less than 3 seconds, no
downslope when welding is stopped.
off
tacking automatics off.
A10 on
if the current is over 100 a and upslope is 0.0
sec., there is a 0.2-second slope from half the
welding current.
off
Current rises directly to maximum.
A12 on
tig = the start of remote control scale.
mma = the end of the scale.
off
remote control as a normal current regulator.
A13 on
searcharc on.
off
searcharc off.
A14 on
during the downslope, the current can be
'frozen' at a certain level by pushing the start
button.
off
freeze function off.
A15 on
the Plus/minus buttons on the remote control
can be used to select the memory channel.
off
the buttons adjust the current.
A16 on
the Plus/minus remote control is always active.
off
the Plus/minus remote control is active only
when selected by pressing the remote button.
flow guard on.
off
flow guard off.
A19 on
automatic control on.
off
Water cooler runs constantly.
A20 on
Water cooler temperature guard selected.
off
temperature guard off.
A21 on
automatic recocnition on, control cannot be
selected if it is not connected.
off
automatic recocnition on/off. Controller can be
selected even if it is not connected.
A22 on*
tail arc on. * 4t log
off** tail arc off. ** minilog