3.2.2.3. Welding panel ACX
– pulsed TIG and MINILOG function with memory
2.
1.
1. 4T-LOG and MINILOG function selections
2. Search arc 5 – 90 % of welding current
3. Start-current 80 – 150 %
4. Minilog-current 10 – 150 % of welding current
5. Tail arc 5 – 90 % of welding current
6. Selection for spot, synergetic quick pulse and long pulse
7. Spot time 0,0 – 10,0 s
8. Pulse current 10 A – power source max.
9. Pulse ratio 10 – 70 % of pulse time
10. Frequency 0.2 – 250 Hz DC-TIG, 0.2 – 20 Hz AC-TIG
11. Base current 10 – 70 % of pulse current
12. MEMORY, memory function
13. Selection of channel in memory function
14. SAVE/memory values
If wanted in SETUP-function you can disable search arc and tail arc functions. Hot Start (Soft
Start)- and Minilog -currents can be disabled by adjusting the values to 100 per cent (the same as
the welding current).