5.2.
Interfaces:
5.2.1.
RS 232 Interface:
Transfer Format:
Transfer Speed:
Transfer Protocol:
yNNNNxCCCxHH:MM:SS.zhtq(CR)
y ................................first character is a space or info (see bellow)
x ................................blank
NNNN ........................start number (four digits), zero at the beginning are not shown
CCC ..........................channels of the timing device
c0 ..............................channel 0start channel
c0M ...........................channel 0manual triggered through keyboard <START>
c1 ..............................channel 1finish channel
c1M ...........................channel 1manual triggered through keyboard <STOP>
c2 ..............................channel 2
c3 ..............................channel 3
c4 ..............................channel 4
c5 ..............................channel 5
c6 ..............................channel 6
c7 ..............................channel 7
c8 ..............................channel 8
RT .............................run time
TT ..............................total time
SQ .............................sequential time
kmh ...........................speed measurement (possible units: km/h, mps, mph)
HH:MM:SS.zhtq ........time in hours, minutes, seconds, and 1/10,000 seconds
(CR) .........................Carriage Return
Info – the following characters are possibel at the first digit:
x ................................blank
? ................................time without valid ID-number
m ...............................time in memory
c ................................cleared time (e.g. with <CLEAR> key
d ................................disqualified time
i .................................manual time input
n ................................input of new ID-number
Example of the RS 232 output (e.g. with program "Backup")
1 c0
15:43:49,8863
2 c0
15:43:50,1647
5 c1
15:43:51,6464
6 c0
15:43:51,9669
7 c1
15:43:52,2467
8 c0
15:43:52,4579
9 c1
15:43:52,6941
15 c0M 15:43:55,6200
16 c1M 15:43:55,8800
17 c0M 15:43:56,4900
m
7 c0
15:43:59,9927
Version: E-2001-12-20
Timy
Timy
Timy
Timy
Timy
1 start bit, 8 data bit, no parity bit, 1 stop bit
9600 Baud factory adjustment
adjustable: 2400, 4800, 19200, 28800, 38400
ASCII
m
8 c1
15:44:00,2849
m
9 c0
15:44:00,5499
m
10 c1
15:44:00,8182
m
11 c0
15:44:01,0366
c
11 c0
15:44:01,0366
n
14 c0
15:44:01,0366
20 c0
15:44:15,0077
22 c0
15:44:15,5165
23 c1
15:44:15,7847
c
23 c1
15:44:15,7847
i
23 c1
15:44:15,7847
Page 23
Need help?
Do you have a question about the Timy and is the answer not in the manual?