Program-specific adjustments

3.1

Countdown time

The countdown time must be chosen variably. Basic adjustment is 50 seconds. You can start
the countdown mit the Start button.
The countdown can be stopped (stop button) and continued (start button) any time. The
countdown time must occur at GAZ-address L ( L ... all addressed displayboards).
If you indicate for the countdown time 0:00h, the programs Lapcounter and Back-up will im-
mediately start. The Timy waits for a start impulse at channel 0. Before receipt, you can add
a new start number if necessary.
3.2

Warning signal (audio warning)

The beep tone should happen at 30, 25 and 10 seconds. The values should be variable and
you should be able to switch them on and off.
3.3

Quantity of Laps

The adjustment of the quantity of laps (3-digit) should be possible at any time. Normally, the
quantity of laps will be indicated before the countdown starts.
Standard lap quantity is 0.
Output of GAZ-address A for participant Red (channel C2).
Output of GAZ-address B for participant Green (channel C4).
If you indicate for lap quantity 0, it will count up. If it is not 0, it will count down of this value.
4

Interfaces and channels

4.1

C0 and C3: Startmachine, C0 also synchronous start

With C0 and C3, the startmachines are controlled. When the countdown time reaches zero a
it gives the start output as well on channel 0. and the Timy switches to the Lapcounter/Back-
up mode. When time does not countdown, than you have to start with channel C0.
4.2

C1 and C4: Lap-counting

C1 and C4 are for counting laps of the two participants red and green.
C1 is for participant red (GAZ-address A).
C4 is for participant green (GAZ-address B).
No output on printer or RS232-interface. C1 and C4 can either be connected to a photocell or
manually controlled with a push button.
If you push C1 or C4 less than 2 seconds, it will count up. If you push them for 2 seconds or
longer it will count back.
4.3

C2 und C5 : Back-up timing

C2 and C5 are for back-up of participants Red and Green.
C2 is Red
C5 is green.
The output on the printer should print the color identification Red or Green instead of the
channel information, the same is valid for RS232 interface.