5.
Technical Data
Processor:
Crystal Frequency:
Time Resolution:
Accuracy:
Program Memory:
Data Memory:
Display:
Keyboard:
Connections:
Channel Extension: per extension 8 channels, max. 99 channels
Power Supply:
Power Consumption: data given at 20°C (68 F)
Charging Duration:
Printer:
Temperature Range: Timy S and P: -5 to 60°C (23 to 140 F)
Measurements:
Weight:
Version: E-2001-12-20
Timy
Timy
Timy
Timy
Timy
Siemens C161 with 3,3 V technology
12,8 MHz with TCXO or standard quartz
1/10.000 s
Temperature Compensated Quartz Oscillator TCXO:
Temperature Range -25 to 50 °C (-13 to 122 F): +/- 2,5ppm (+/- 0,009 s/h)
Aging:
At 25°C (77 F) trimmed:
Standard Quartz:
Temperature Range -25 to 50 °C (-13 to 122 F): +/- 50 ppm (+/- 0,18 s/h)
Aging:
At 25°C (77 F) trimmed:
FLASH Memory with 8 MBit
RAM with 2 MBit (about 12.000 times)
monochrome LCD graphic display , 128 x 64 pixel, available with
standard-
or with extended temperature range
silicon keyboard, 26 keys
1 x DIN-socket for photocell (7)
1 x banana socket pair – start input (5)
1 x banana socket pair - finish input (6)
1 x banana socket pair – display board (4)
1 x D-Sub 25-pin (3)
• 9 timing channels
• RS 232 (PC-connection)
• display board
• RS 485 (network)
• power supply (7–15 VDC out)
1 x USB (1)
1 x power supply (7 - 15 VDC in) (2)
Internal:
6 x AA-Alkaline
6 x 2 Ah or
6 x AA-NiCd 6 x 1 Ah or
6 x AA-NiMH 6 x 1,5 Ah
External:
Power Supply NG13, 12 V battery or 7-15 VDC
Alkali:
without printer about 50 hours
NiCd:
without printer about 25 hours
NiMH:
without printer about 38 hours
Alkali:
not possible with printer
NiCd:
about 3000 lines
NiMH:
about 4500 lines
depending on the rechargeable battery, max. about 14 hours
graphic thermo printer, max. 5 lines per sec.
Timy XE and PXE: -20 to 60°C (-4 to 140 F)
Timy S and XE:
204 x 91 x 50 mm
Timy P and PXE:
307 x 91 x 65 mm
Timy S and XE:
450 g (no battery)
Timy P and PXE:
650 g (no battery and paper)
max. +/- 1 ppm per year
+/- 0,1 ppm
max. +/- 5 ppm per year
+/- 0,1 ppm