Table 10-1
Numeric Codes and Text Messages (continued)
Control panel message
2203-Setup error during MEBx execution
2204-Inventory error during MEBx execution
2205-Interface error during MEBx execution
2211-Memory not configured correctly for
proper MEBx execution.
2212-USB Key Provisioning failure writing to
device
2217-ME Firmware Version request failure
2218-ME Firmware Version should be
updated
Description
MEBx selection or exit resulted in a setup
failure.
BIOS information passed to the MEBx
resulted in a failure.
MEBx operation experienced a hardware
error during communication with ME.
DIMM1 or XMM1 is not installed.
USB device used for USB key provisioning
will not allow BIOS to update provision file
properly.
ME firmware is not properly responding to
BIOS query for version information.
ME firmware must be updated to match
current functionality contained in the system
BIOS.
Recommended action
1.
Reboot the computer.
2.
Unplug the power cord, re-seat the
memory modules, and reboot the
computer.
3.
If the memory configuration was
recently changed, unplug the power
cord, restore the original memory
configuration, and reboot the computer.
4.
If the error persists, replace the system
board.
1.
Reboot the computer.
2.
If the error persists, update to the latest
BIOS version.
3.
If the error still persists, replace the
system board.
1.
Reboot the computer.
2.
If the error persists, update to the latest
BIOS version.
3.
If the error still persists, replace the
system board.
Make sure there is a memory module in the
black DIMM1 socket and that it is properly
seated.
1.
Try a different USB key device for
provisioning.
2.
If the error persists, update to the latest
BIOS version and ME firmware version.
3.
If the error still persists, replace the
system board.
1.
Reboot the computer.
2.
If the error persists, update to the latest
BIOS version and ME firmware version.
3.
If the error still persists, replace the
system board.
1.
Update to the latest ME firmware
version.
2.
If the error persists and system BIOS
has been recently updated, restore
previous system BIOS version.
3.
If the error still persists, replace the
system board.
POST Numeric Codes and Text Messages