Dalsa Pantera TF 11M4 User Manual page 47

Progressive scan monochrome camera
Hide thumbs Also See for Pantera TF 11M4:
Table of Contents

Advertisement

Pantera TF 11M and 6M User's Manual
Symbol
SMART SYNC)
tTRANSFER
falling edge of EXSYNC to
start of readout in SMART
SYNC, pretrigger=0)
tREADOUT
readout time, pretrigger=0)
tOVERHEAD
readout before next EXSYNC)
TwSYNC_INT
integration pulse, not SMART
SYNC)
TwSYNC_INT
integration pulse, in SMART
SYNC)
tFRAME PERIOD
frame period)
tFL
LVAL)
tLINE
tLVAL_LOW
time)
tLF
end of FVAL)
Table 13: 11M Dual Output Timing
Symbol
twSYNC
twSYNC
SMART SYNC)
tTRANSFER
falling edge of EXSYNC to
start of readout in SMART
SYNC, pretrigger=0)
tREADOUT
readout time, pretrigger=0)
tOVERHEAD
readout before next EXSYNC)
TwSYNC_INT
integration pulse, not SMART
SYNC)
TwSYNC_INT
DALSA
(time from
(frame
(time after
(min
(min
(min
(time from FVAL to first
(LVAL high time)
(LVAL low
(time from last LVAL to
(min sync pulse,
not SMART SYNC)
(min sync pulse in
(time from
(frame
(time after
(min
(min
Binning
1 x 1
2 x 2
1.0ms
1.1ms
375ms
224ms
125us
125us
1us
1us
1us
1us
376ms
225ms
28.5us
55.5us
112us
112us
29us
56us
0ns
25ns
Binning
1 x 1
2 x 2
100ns
100ns
1us
1us
690us
720us
226ms
150ms
125us
125us
1us
1us
1us
1us
47
4 x 4
1.2ms
149ms
125us
1us
1us
150ms
110us
112us
112us
25ns
4 x 4
100ns
1us
774us
112ms
125us
1us
1us
03-032-10096-05