Channel Description - Nibe FIGHTER 600P Installation And Maintenance Instructions Manual

Table of Contents

Advertisement

General information for the installer
Use the Channel selection button to scroll forward
through the numerical display's channels to see the
required reading or setting
The significance/function of the different channels is as fol-
lows:
1 Boiler temperature
2 Flow temperature
3 Outside temperature
4 Evaporation temperature
5 Extract air temperature
6 Heating curve
7 Heating curve offset
8 Hot water temperature (at the hot water sensor, the tem-
perature above the sensor is usually higher)
9 Set blocking temperature (outdoor temperature) for the
immersion heater.
10 Calculated flow temperature
11 Service position. When the value "00" is shown a return
to channel 1 will occur the next time the button is
pressed. The value can be changed to "01" by pressing
the Operating mode button. Channel 12 is then shown
the next time the Channel selection button is pressed.
12 Deviation between the calculated and true flow
13 Non active channel. The numerical display shows "-- --".
14 Selected operating mode using the Operating mode but-
ton with the following significance:
01 Circulation pump running (for the heating system),
immersion heater connection permitted
02 Circulation pump running (for the heating system),
immersion heater blocked
03 Circulation pump not running (for heating system),
immersion heater blocked
Pressing the Operating mode button when channel 14 is
shown also resets the compressor's pressure-compensating
time. This should only be carried out by a professional with
expertise within refrigeration. The two hour delay concerning
the immersion heater's third step, which is activated when
the switch is set to "1", is also reset.
15 Shows the connected output step according to the fol-
lowing:
01 and 02: compressor
03 Compressor and step 1, immersion heater (3 kW)
04 Compressor and step 2, immersion heater (6 kW)
05 and 06: Compressor and step 3, immersion heater
(9 kW)
Pressing the Operating mode button connects the next high-
er step irrespective of the control programme's outcome.
16 Non active channel. The numerical display shows "-- --".
17 Selected operating mode with ventilation adjustment,
see Commissioning and adjustment - Setting the ventila-
tion
00 Normal mode, ventilation adjustment not activated
01 Highest fan speed, outdoor air damper closed

Channel description

18 Non active channel. The numerical display shows "----".
19 Shows the current status with regard to heating/hot
20 Shows the boiler temperature at previous reading
21 Shows the automatic output control's action during the
22 Shows the selected ventilation mode (selection made
23 Shows whether correction of the Heating curve offset
25 Selected temperature in step 1 regarding the drying
26 Selected number of days in step 2 regarding the drying
27 Selected temperature in step 2 regarding the drying
FIGHTER 600P
02Normal fan speed, outdoor air damper closed
03Highest fan speed, outdoor air damper open
water production according to the following:
01Heating required, no hot water requirement
02No heating requirement, hot water required
05Boiler temperature exceeding the maximum permit-
ted
06No heating requirement, no hot water requirement
07No hot water requirement, summer mode (immer-
sion heater and circulation pump blocked via the
operating mode button).
09Hot water required, summer mode (immersion
heater and circulation pump blocked via the operat-
ing mode button).
11Periodic heating production in progress
12Periodic hot water production in progress
(readings are made every fourth minute)
previous action regarding connection and disconnec-
tion of the output step according to channel 15 (actions
are taken fourth minute).
00Neither connection nor disconnection took place
01Connection of one output step took place
02Disconnection of one output step took place
04Hot water mode
05Hot water mode in summer mode (immersion heater
and circulation pump blocked via the operating mode
button).
using the Ventilation button) according to the following:
01 Normal ventilation active
02 Forced ventilation active (party mode)
via an external switch is actuated, see Electrical con-
nection - Remote/room control.
00Correction is not activated
-3 Correction activated (Heating curve offset lowered
three steps)
24Selected number of days in step 1 regarding the dry-
ing process
process
process
process.
Control reverts to only showing channels 1 to 11 after
approximately 4 hours or by changing the value from
01 to 00 under channel 11.
For the Installer
13