FIGHTER 600P you should read through the For Home Owners section in this Installation and Maintenance Instruction. FIGHTER 600P is a combined exhaust air and out- door air heat pump. This means it utilises energy in ventilation air and outdoor air when this does not fall below -5 °C.
For Home Owners System description Principle of operation FIGHTER 600P consists of an electric boiler with enam- elled water heater and a heat pump that recovers energy Vented air Outdoor air Exhaust air Avluft Uteluft Frånluft from ventilation air and outdoor air when this is - 5 °C or warmer.
Flashing Immersion heater or part of the for example, a floor heating system. immersion heater blocked via cen- tralised load control/tariff control or due to a 2 hour delay with start of FIGHTER 600P. FIGHTER 600P...
Pressing it once more stops the circulation goes out in this operating mode. pump as well. However, note that the circulation NOTE! If FIGHTER 600P is installed in a large pump is operational during hot water heating. house so that no outdoor air is utilised only...
If the room temperature is low, increase the heating curve selection setting by one step. FIGHTER 600P offers the possibility to block immer- If the room temperature is high, reduce the heating sion heater operations as a function of the outdoor curve selection setting by one step.
A suitable setting on the Increase/reduce knob is - 2 for radiator systems and -1 for floor heating. - 10 - 20 - 30 - 40 °C HEATING OUTSIDE TEMPERATURE CURVE OFFSET Diagram with offset +2 FIGHTER 600P...
Cleaning the outdoor air damper When cleaning the outer wall grille even the outdoor air damper in FIGHTER 600P should be cleaned. First switch off the heat pump. Now open the upper service cover as described in the section Maintenance rou- tines - Cleaning the air filter.
- High extract air temperature. It is normal that the extract air temperature varies. Sacrificial anode test FIGHTER 600P has two safety valves, one for the heating system and one for the water heater. ANODEN-TESTER 1, 2, ...
Automatic heating control system settings not cor- High pressure pressostat rect. The reversing valve (43) is set to manual mode. If the operating disturbance cannot be rectified by means of the above an installation engineer should be called. If necessary set the switch to FIGHTER 600P...
It is usually easier to start the circulation pump with FIGHTER 600P running, switch (8) set to “1”. If help- ing the circulation pump to start is performed with FIGHTER 600P running, be prepared for the screw- driver to jerk when the pump starts.
Route pipes so they are not fixed to an internal wall that backs on to a bedroom or living room. FIGHTER 600P has a venting screw located on the front edge at the top. This should be easily accessible, which should be considered during installation.
Control reverts to only showing channels 1 to 11 after tion approximately 4 hours or by changing the value from 00 Normal mode, ventilation adjustment not activated 01 to 00 under channel 11. 01 Highest fan speed, outdoor air damper closed FIGHTER 600P...
Pipe connections General Docking Pipe installation must be carried out in accordance Other heat sources can be docked to FIGHTER 600P. with current norms and directives. Accessories are needed. Contact NIBE AB for infor- mation. The system requires a low-temperature design of the radiator circuit.
Duct connections should be made via flexible hoses, which must be installed so that they are easy to replace. FIGHTER 600P is connected so that all ventilation air The extract air and outdoor air ducts are to be insulated except the kitchen fan passes the evaporator (62) in using diffusion-proof material along their entire lengths.
The temperature limiter is reset by firmly pressing in the sensor capsule. the rubber membrane. 1, 2, ... – – U-PUMPE PARALLEL – RUNDSTEUERUNG FERNSTEUERUNG AUSSENFÜHLER SCHUTZKLEINSPANNUNG SELV Max phase current Output Max load Group fuse (kW) phase (A) 12.8 14.9 19.2 FIGHTER 600P...
The microprocessor in FIGHTER 600P corrects the originally selected setting for Heating curve offset by External switch or External three steps downwards.
(35). See the section Pipe connec- 3, 4, 5 and 6 A and B tions - Pump and pressure drop diagram. Make (no electrical output available) sure that the switch is not in an intermediate posi- tion. FIGHTER 600P...
11. Channel 12 up to channel 27 are dries at the right rate.FIGHTER 600P is equipped with this function. This means you can set a program so the service channels and may only be managed by that a constant flow temperature is obtained during a a professional.
For the Installer Setting the automatic heating control system Heating curve offset -2 Setting using diagrams FIGHTER 600P is equipped with outdoor temperature HEATING CURVE KURVLUTNING controlled automatic controls. This means the flow °C temperature is regulated in relation to the current out- 15 14 13 12 door temperature.
Service - Opening the cover to the distribu- tion box. The normal position on the miniature circuit-breaker (7) is “1” (left). The above may only be carried out by persons with the relevant expertise. Note the distribu- tion box contains live parts. FIGHTER 600P...
- Emptying the water heater. Dismantle the inspection cover (58). Replace the sacrificial anode in the inspection cover. Re-assemble in the reverse order. Sacrificial anode replacement can be eliminated if a direct current anode is fitted. FIGHTER 600P...
Measuring principle Copper pipe Compression ring Klämring Cu-rör A, B and C: See “Connection” in the “List of components”. When running pipes in the hatched area, make sure there is space to change the expansion vessel. FIGHTER 600P...
NOTE! In this output step only 2 kW is obtained in standby mode. 2 x 1 kW White 3 x 2 kW Brown 9.0 kW (delivery output) All cables are connected to the immersion heater. 3 x 1 kW White 3 x 2 kW Brown FIGHTER 600P...
For the Installer Docking Docking to a gas boiler FIGHTER 600P is suitable for docking to a gas boiler. The electrical connection between the gas boiler and This then replaces the immersion heater in the heat the heat pump is made via a two-pole cable. When the pump.
For the Installer Docking Docking to the accumulator tank In order to utilise special tariffs the FIGHTER 600P water to the FIGHTER’s heating circuit. This takes can be supplemented with an accumulator tank (with place until there is no longer a need of the energy sup- immersion heater), which supplies a heat supplement plement.