Filling the heating system ........15 Venting the heating system ......... 15 Starting ..............16 Setting the ventilation .......... 16 Readjustment ............16 Draining the heating system ........ 16 Draining the water heater ........16 Operating instructions for enclosed clock thermostat ..........17 FIGHTER 200P...
For Home Owners General In order to get the ultimate benefit from your heat pump FIGHTER 200P you should read through the For Home Owners section in this Installation and Maintenance Instruction. FIGHTER 200P is an exhaust air heat pump. This means it utilises energy in ventilation air and uses this energy for hot water and heating the house.
The heat pump must be installed in a ventilation system intended for mechani- cal exhaust air. A DC fan is used in FIGHTER 200P. The output of the immersion heater is 3,0 kW. When...
On achieving the set temperature, the For time and temperature settings see section "Com- circulation pump inside FIGHTER 200P will stop. missioning and adjusting" – "Operating instructions for enclosed clock thermostat". In order to set different intervals with a temperature...
Check that the filter is not damaged. New original filters can be ordered from NIBE. ■ Re-assembly takes place in the reverse order. The cleaning time intervals vary depending on the amount of dust in the exhaust air.
Jättegammal modell Cleaning the ventilation devices Checking the safety valves FIGHTER 200P has three safety valves, one for the heating system and two for the water heater. The heating system safety valve (52) must be com- pletely tight, but the hot water safety valve (47) may release some water after hot water has been used.
(42). Contact the installer. ■ Thermostat (3) for immersion heater set too low. NOTE! In all correspondence with NIBE state the serial number _ _ _ _ _ _ _ _ _ _ _ _ _ _ If the operating disturbance cannot be rectified by means of the above an installation engineer should be called.
Low pressure pressostat. Normally this pressostat resets automati- Auto cally, so it does not have a resetbutton. Helping the circulation pump to start ■ Shut down FIGHTER 200P by turning the power switch (8) to "0". ■ Remove the lower front cover. Venting screw Luftningsskruv Entlüfterschraube...
The initial Normally it is no problem to install FIGHTER 200P in pressure of the expansion vessel must be stated in the hard water areas since the maxing working tempera- inspection document.
(expansion valve) and the storage cylinder. heater and 70 litres in the boiler section. The pressure vessel in the FIGHTER 200P is approved for max 9.0 bar (0.9 MPa) in the water heater and 2.5 bar (0.25 MPa) in the double shell section.
Ventilation connection Ventilation flow Duct installation FIGHTER 200P is connected so that all ventilation air To prevent fan noise being transferred to the exhaust air except the kitchen fan passes the evaporator (62) in devices, it may be a good idea to install a silencer in the the heat pump.
Connecting a fan switch to 88 °C; it can be manually reset by pressing the but- ton on the temperature limiter. FIGHTER 200P gives the possibility to connect a two way switch for choosing between normal ventilation and reduced ventilation.
Ampere fuse shall be used. NOTE! Relevant electrical standards must be considered. Immersion heater FIGHTER 200P is delivered with a 3 kW immersion heater (1). It is started and stopped via the micro- proessor card (34). If a failure occurs there is a tem- perature limiter (6) (thermal cut-out) that is stopping the immersion heater.
(6) has not tripped (press hose (147) shall be removed. firmly the knob). FIGHTER 200P is supplied with a limiting valve (5) mounted on the outlet pipe. This one allows to set a maximum outlet temperature in order Venting the heating system to protect the floor in an existing floor heating system.
(51) using an R15 (1/2") hose coupling. Remove the cover (80) from the valve (51). Screw on the hose coupling and open the valve (51). Open the safety val- ve (52) to let air into the system. FIGHTER 200P...
When the desired start times have all been entered Operating mode selection the arrow will return within one minute from work Plus/minus keys for setting daily temperature and time day / rest day 5 / F to work day FIGHTER 200P...
Periodical temperature increase FIGHTER 200p is equipped with the function for perio- which effects the economies slightly negative. Also dical temperature increase. This means that the tempe- note that while this heating the immersion heater is rature will be put up to 60°...
Work on the refrigerant system must be done by authorised personnel in accor- dance with the relevant legislation on refrigerants, supplemented by additio- nal requirements for flammable gas, for example, product knowledge as well as service instruction on gas systems with flammable gases. FIGHTER 200P...
158 Circuit board for fan speed 107 Expansion vessel, tap water 108 Tundish from safety valve 109 Tundish from pressure valve 148 Pressure reduction valve 149 Connection for flexible hose to CW-side 150 Connection for flexible hose to heating-side FIGHTER 200P...
When running pipes in the hatched area område för att underlätta service to facilitate servicing. Kupferrohr Klemmring A, B and C: see "Connection" in "Component list". Pipes must not be run from the floor in the area indi- cated by dots. FIGHTER 200P...
Total Power input 0,535 kW Current 2,7 A Rating condition Exhaust air: 150 m 3 /h Air flow Inlet dry bulb temperature 20 °C Inlet wet bulb temperature 12 °C Water: Inlet temperature 40 °C Outlet temperature 45 °C FIGHTER 200P...