Nibe FIGHTER 200P Installation And Maintenance Instructions Manual

Nibe FIGHTER 200P Installation And Maintenance Instructions Manual

Immersion heater 3 kw
Table of Contents

Advertisement

MOS GB 0511-1
FIGHTER 200P
INSTALLATION AND MAINTENANCE INSTRUCTIONS
R
511052
60
40
80
°C
20
0
120
T
G
FIGHTER 200P
Immersion heater 3 kW
100
3
1
2

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the FIGHTER 200P and is the answer not in the manual?

Questions and answers

Summary of Contents for Nibe FIGHTER 200P

  • Page 1 INSTALLATION AND MAINTENANCE INSTRUCTIONS FIGHTER 200P MOS GB 0511-1 511052 Immersion heater 3 kW FIGHTER 200P °C...
  • Page 2 Fighter Fighter 310P 310P Fighter 310P Fighter 310P Fighter Fighter 310P 310P Fighter Fighter 310P 310P...
  • Page 3: Table Of Contents

    Preparations ............15 Filling the heating system ........15 Venting the heating system ........15 Starting ..............16 Setting the ventilation .......... 16 Readjustment ............16 Draining the heating system ........ 16 Draining the water heater ........16 FIGHTER 200P...
  • Page 4: General

    For Home Owners General In order to get the ultimate benefit from your heat pump FIGHTER 200P you should read through the For Home Owners section in this Installation and Maintenance Instruction. FIGHTER 200P is an exhaust air heat pump. This means it utilises energy in ventilation air and uses this energy for hot water and heating the house.
  • Page 5: System Description

    For Home Owners System description Principle of operation FIGHTER 200P consists of an electric boiler with cop- Exhaust air Extract air Avluft Frånluft per lined water heater and a heat pump that recovers energy from ventilation air. The recovered energy is supplied to the heat pump.
  • Page 6: Front Panel

    Not lit Immersion heater is not in opera- tion. Automatic heating control system The heat emission is controlled by means of a room thermostat. On achieving the set temperature, the cir- culation pump inside FIGHTER 200P will stop. FIGHTER 200P...
  • Page 7: Maintenance Routines

    Check that the filter is not damaged. New original filters can be ordered from NIBE. ■ Re-assembly takes place in the reverse order. The cleaning time intervals vary depending on the amount of dust in the exhaust air.
  • Page 8: Cleaning The Ventilation Devices

    Maintenance routines Cleaning the ventilation devices Checking the safety valves FIGHTER 200P has three safety valves, one for the heating system and two for the water heater. The heating system safety valve (52) must be com- pletely tight, but the hot water safety valve (47) may release some water after hot water has been used.
  • Page 9: Low Temperature Or Lack Of Hot Water

    (42). Contact the installer. ■ Thermostat (3) for immersion heater set too low. NOTE! In all correspondence with NIBE state the serial number 089_ _ _ _ _ _ _ _ _ _ _ If the operating disturbance cannot be rectified by means of the above an installation engineer should be called.
  • Page 10: Indications On The Display

    Low pressure pressostat. Normally this pressostat resets automati- cally, so it does not have a resetbutton. Helping the circulation pump to start ■ Shut down FIGHTER 200P by turning the power switch (8) to "0". ■ Remove the lower front cover.
  • Page 11: General Information For The Installer

    Normally it is no problem to install FIGHTER 200P in vessel. The initial pressure of the expansion vessel hard water areas since the maxing working tempera- must be stated in the inspection document.
  • Page 12: Pipe Connections General

    70 litres in the boiler section. or bends in the pipework. See following picture. The pressure vessel in the FIGHTER 200P is approved for max 9.0 bar (0.9 MPa) in the water heater and 2.5 bar (0.25 MPa) in the double shell section.
  • Page 13: Tap Water Connection

    Heat pump so that any contaminants do not FIGHTER 200P Water heater damage the components parts. The heat pump should be supplemented with an elec- tric water heater if a bubble pool or other significant consumer of hot water is installed.
  • Page 14: Ventilation Connection

    Ventilation connection Ventilation flow Duct installation FIGHTER 200P is connected so that all ventilation air To prevent fan noise being transferred to the exhaust air except the kitchen fan passes the evaporator (62) in devices, it may be a good idea to install a silencer in the the heat pump.
  • Page 15: Electrical Connections

    Immersion heater any service work must be done in strict conformity to current regulations FIGHTER 200P is delivered with a 3 kW immersion under the supervision of a qualified heater (1). It is started and stopped via the micropro- electrician.
  • Page 16: Connecting The Room Thermostat

    Also consider any draughts from exterior doors. Neither must the unit be affected by solar incident radiation. FIGHTER 200P...
  • Page 17: Commissioning And Adjusting

    (6) has not tripped (press must be closed. firmly the knob). FIGHTER 200P is supplied with a ■ Open the filling valve (49) to fill the boiler and the limiting valve (5) mounted on the outlet pipe. This one allows to set a maximum outlet temperature in order radiator system.
  • Page 18: Starting

    (51) using an R15 (1/2") hose coupling. Remove the cover (80) from the valve (51). Screw on the hose coupling and open the valve (51). Open the safety val- ve (52) to let air into the system. FIGHTER 200P...
  • Page 19: Temperature Levels

    Periodical temperature increase FIGHTER 200p is equipped with the function for perio- immersion heater, which effects the economies slight- dical temperature increase. This means that the tem- ly negative.
  • Page 20: Service

    Work on the refrigerant system must be done by authorised personnel in accor- dance with the relevant legislation on refrigerants, supplemented by additional requirements for flammable gas, for example, product knowledge as well as service instruction on gas systems with flammable gases. FIGHTER 200P...
  • Page 21: Electrical Circuit Diagram

    For the Installer Electrical circuit diagram Mode 0 Läge 0 Mode 1 Läge 1 Mode 2 Läge 2 Mode 3 Läge 3 Relä 3 Relä 1 Relä 2 AC/DC L1 N 230 V 12 V FIGHTER 200P...
  • Page 22: Component Locations

    For the Installer Components locations 31 32 Auto Fram- Radiator ledning system radiatorer outlet v.v. k.v. Radiator ter- ledning system inlet radiatorer FIGHTER 200P...
  • Page 23: List Of Components

    98 Overflow water discharge ..........PVC-pipe, 32 mm outer diameter 99 Collecting funnel for overflow water 103 Serial No. plate 104 Temperature and pressure valve 105 Pressure reduction valve 107 Expansion vessel, tap water 108 Tundish from safety valve 109 Tundish from pressure valve FIGHTER 200P...
  • Page 24: Dimensions

    When running pipes in the hatched area område för att underlätta service to facilitate servicing. A, B and C: see "Connection" in "Component list". Pipes must not be run from the floor in the area indicated by dots. FIGHTER 200P...
  • Page 25: Enclosed Kit

    For the Installer Enclosed kit Expansion vessel, tap water (is delivered separately) Accessories Room thermostat RT 10 Part no 418 366 Heightening console Height: 125 mm Part no 089195 FIGHTER 200P...
  • Page 26: Technical Specifications

    Concerns settings on delivery A-weighted sound power level (LWA). The value varies with the selected fan curve. A-weighted sound pressure level (LpA). The value varies with the damping capacity of the room. These values apply with a damping of 4 dB. FIGHTER 200P...
  • Page 28 Tel: +46 - (0)433 - 73 000 NIBE AB Box 14 Fax: +46 - (0)433 - 73 190 Järnvägsgatan 40 E-mail: info@nibe.se SWEDEN SE-285 21 MARKARYD www.nibe.com...