1 1

Listing and Code Approvals

A. Appliance Certifi cation
MODELS: Cosmo-SXT-IPI, Cosmo-GXT-IPI
LABORATORY: Underwriters Laboratories, Inc. (UL)
TYPE: Vented Gas Appliance Heaters
STANDARD: ANSI Z21.88B-2009 • CSA 2.33A - 2008
This product is listed to ANSI standards for "Vented Gas
Appliance Heaters" and applicable sections of "Gas Burn-
ing Heating Appliances for Manufactured Homes and
Recreational Vehicles", and "Gas Fired Appliances for
Use at High Altitudes".
NOT INTENDED FOR USE AS A PRIMARY HEAT SOURCE.
This appliance is tested and approved as either supplemen-
tal room heat or as a decorative appliance. It should not be
factored as primary heat in residential heating calculations.
Note: To assure top performance, safety and effi ciency,
inserts must be installed with an approved fl ue liner as per
CAN/CGA B-149 or National Fuel Gas Code ANSI Z223 and
these instructions.
Note: This installation must conform with local codes. In the
absence of local codes you must comply with the National
Fuel Gas Code, ANSI Z223.1-latest edition in the U.S.A. and
the CAN/CGA B149 Installation Codes in Canada.
B. BTU Specifi cations
Models
(U.S. or Canada)
Cosmo-SXT-IPI (NG)
(2000-4500 FT.)
Cosmo-GXT-IPI (NG)
(2000-4500 FT.)
Cosmo-SXT-IPI (LP)
(2000-4500 FT.)
Cosmo-GXT-IPI (LP)
(2000-4500 FT.)
4
Maximum
Minimum
Input
Input
BTU/h
BTU/h
US
24,000
18,000
(0-2000 FT.)
CANADA
21,600
16,200
US
29,000
20,000
(0-2000 FT.)
CANADA
26,100
18,000
US
24,000
18,000
(0-2000 FT.)
CANADA
21,600
16,200
US
29,000
21,000
(0-2000 FT.)
CANADA
26,100
18,900
Heat & Glo • Cosmo-SXT-IPI, Cosmo-GXT-IPI • 2203-900 Rev. E • 1/10
C. High Altitude Installations
U.L. Listed gas appliances are tested and approved with-
out requiring changes for elevations from 0 to 2000 feet in
the U.S.A. and Canada.
When installing this appliance at an elevation above 2000
feet, it may be necessary to decrease the input rating
by changing the existing burner orifi ce to a smaller size.
Input rate should be reduced by 4% for each 1000 feet
above a 2000 foot elevation in the U.S.A., or 10% for el-
evations between 2000 and 4500 feet in Canada. If the
heating value of the gas has been reduced, these rules
do not apply. To identify the proper orifi ce size, check with
the local gas utility.
If installing this appliance at an elevation above 4500 feet
(in Canada), check with local authorities.
Do NOT use this appliance if any part has been under water.
Immediately call a qualifi ed service technician to inspect the
appliance and to replace any part of the control system and
any gas control which has been under water.
D. Non-Combustible Materials Specifi cation
Material which will not ignite and burn. Such materials are
those consisting entirely of steel, iron, brick, tile, concrete,
slate, glass or plasters, or any combination thereof.
Materials that are reported as passing ASTM E 136,
Standard Test Method for Behavior of Materials in a
Vertical Tube Furnace at 750º C, shall be considered
non-combustible materials.
Orifi ce
E. Combustible Materials Specifi cation
Size
(DMS)
Materials made of or surfaced with wood, compressed
paper, plant fi bers, plastics, or other material that can ig-
42
nite and burn, whether fl ame proofed or not, or whether
43
plastered or unplastered shall be considered combustible
materials.
38
F. Electrical Codes
39
NOTICE: This appliance must be electrically wired and
grounded in accordance with local codes or, in the absence
53
of local codes, with National Electric Code ANSI/NFPA
70-latest edition or the Canadian Electric Code CSA
54
C22.1.
• A 110-120 VAC circuit for this product must be protected
52
with ground-fault circuit-interrupter protection, in compliance
53
with the applicable electrical codes, when it is installed in
locations such as in bathrooms or near sinks.
WARNING