Installing Vent Pipe and Appliance

A. Venting Components
CAUTION
Sharp Edges
• Wear protective gloves and safety
glasses during installation.
The vertical vent termination system installed on this model
includes:
• One length of 3-inch fl exible vent pipe for combustion
air (included with vent kit). Pipe will be either a 4-foot
or 30-foot section depending on which kit is being used
in the application.
• Flexible vent pipe for exhaust air (included with vent kit).
• One pipe-to-cap adaptor (included with vent kit).
• One vertical termination cap (included with vent kit).
EXHAUST
AIR
VENT PIPE
Figure 7.1
TERMINATION
CAP
INLET AIR
VENT PIPE
INLET AIR STARTING COLLAR
STARTING COLLAR BRACKET
EXHAUST STARTING COLLAR
Heat & Glo • Cosmo-SXT-IPI, Cosmo-GXT-IPI • 2203-900 Rev. E • 1/10
B. Connecting Vent Pipe
Reference instructions in the termination kit.
• Install the 3-inch fl exible vent pipe(s) down through the
chimney.
• Use three screws to secure the exhaust fl exible vent
pipe to the exhaust starting collar on top of appliance
with three screws (see Figure 7.1).
• Use 3 screws to attach either a 4 foot or 30 foot section
of inlet air vent to the inlet collar on the collar slide plate
(see Figure 7.1).
NOTE: The collar slide plate may be removed from appliance
to aid installation.
• Seal opening between fl ex vent and chimney just above
insert. Unfaced fi berglass insulation may be used for this
purpose.
LOCKING TAB
EXHAUST STARTING COLLAR
INLET AIR STARTING COLLAR
STARTING COLLAR BRACKET