Gas Supply Pressure Measurement; White-Rodgers 36G54 Gas Valve; Gas Manifold Pressure Measurement And Adjustment - Goodman GMH8 Installation Instructions Manual

Gas-fired warm air furnace
Table of Contents

Advertisement

3.
White-Rodgers
Model
36G54:
Push
switch
to the
OFF
position.
4.
Close
manual
gas shutoff
valve
external
to the furnace.
5.
Replace
the door on the unit.
Gas
Shutoff
Valve
GAS SUPPLY
PRESSURE
MEASUREMENT
To Furnace
_lb CAUTION
To
PREVENT
UNRELIABLE
OPERATION
OR EQUIPMENT
DAMAGE,
THE
INLET
GAS
SUPPLY
PRESSURE
MUST
BE AS SPECIFIED
ON THE
UNIT
RATING
PLATE
WITH
ALL
OTHER
HOUSEHOLD
GAS
FIRED
APPLIANCES
OPERATING.
WHITE-RODGERS
36G54
GAS VALVE
The
line pressure
supplied
to the gas valve
must
be within
the
range
specified.
The
supply
pressure
can be measured
at the
gas valve
inlet pressure
boss
or at a hose
fitting
installed
in the
gas piping
drip leg.
The supply
pressure
must
be measured
with
the burners
operating.
To measure
the gas supply
pressure,
use
the following
procedure.
Open to
Atmo.=
,here
t
Manometer
Manometer
I
Hose
_r
Pressure
Boss
_
\
Inlet
Pressure
Boss
OntOff
Switch
High
Fire Regulator
Jst
Regulator
Low
Fire
Regulator
Adjust
Hig
Coaxial
Coil
Coil
Terminal
(HI)
Terminal
(M)
Common
Terminal
(C)
1.
2.
White-Rodgers
Model
36G54
Connected
to Manometer
Turn
OFF gas to furnace
at the manual
gas shutoff
valve
external
to the furnace.
Connect
a calibrated
water
manometer
(or appropriate
gas
pressure
gauge)
at either
the gas valve
inlet pressure
boss
or the gas piping
drip leg.
Open To
With
Manometer
Hose
Manometer
Measuring
Inlet Gas Pressure
(AIt. Method)
NOTE:
If measuring
gas pressure
at the drip leg, a field supplied
hose
barb
fitting
must
be installed
prior
to making
the hose
connection.
If using
the inlet pressure
boss
on the gas valve,
then
use the 36G Valve
Pressure
Check
Kit, Goodman
Part No.
0151K00000S.
3.
Turn
ON the gas supply
and operate
the furnace
and all
other
gas consuming
appliances
on the same
gas supply
line.
4.
Measure
furnace
gas supply
pressure
with
burners
firing.
Supply
pressure
must
be within
the range
specified
in the
Inlet Gas Supply
Pressure
table.
I
Inlet Gas Supply Pressure
t Natural Gas f
Minimum:
5.0" w.o. 1. Maximum:10.0"
w.c.
Propane Gas|
Minimum: 11.0" w.c. | Maximum:13.0"
w.c.
If supply
pressure
differs
from
table,
make
the
necessary
adjustments
to pressure
regulator,
gas
piping
size,
etc.,
and/or
consult
with
local
gas utility.
5.
Turn
OFF gas to furnace
at the manual
shutoff
valve
and
disconnect
manometer.
Reinstall
plug
before
turning
on
gas to furnace.
6.
Turn
OFF any unnecessary
gas appliances
started
in step
3.
GAS MANIFOLD
PRESSURE
MEASUREMENT
AND ADJUSTMENT
_,
CAUTION
To
PREVENT
UNRELIABLE
OPERATION
OR
EQUIPMENT
DAMAGE,
THE
GAS
MANIFOLD
PRESSURE
MUST
BE AS SPECIFIED
ON
THE UNIT
RATING
PLATE.
ONLY
MINOR
ADJUSTMENTS
SHOULD
BE MADE
BY ADJUSTING
THE GAS
VALVE
PRESSURE
REGULATOR.
Only small
variations
in gas pressure
should
be made
by adjusting
the gas valve
pressure
regulator.
The manifold
pressure
must
be
measured
with
the burners
operating.
To measure
and adjust
the manifold
pressure,
use
the following
procedure.
23

Advertisement

Table of Contents
loading

This manual is also suitable for:

Gdh8

Table of Contents