Upflow Installations; Gas Piping Checks; Propane Gas Tanks And Piping - Goodman GMH8 Installation Instructions Manual

Gas-fired warm air furnace
Table of Contents

Advertisement

• install
a manual
shutoff
valve
between
the gas meter
and
unit within
six feet of the unit.
If a union
is installed,
the
union
must
be downstream
of the manual
shutoff
valve,
between
the shutoff
valve
and the furnace.
• Tighten
all joints
securely.
• Connect
the furnace
to the building
piping
by one
of the
following
methods:
--
Rigid
metallic
pipe and fittings.
--
Semi-rigid
metallic
tubing
and
metallic
fittings.
Aluminum
alloy
tubing
must
not be used
in exterior
locations.
--
Use
listed
gas
appliance
connectors
in accordance
with
their
instructions.
Connectors
must
be fully
in
the same
room
as the furnace.
Protect
connectors
and
semi-rigid
tubing
against
physical
and thermal
damage
when
installed.
Ensure
aluminum-alloy
tubing
and connectors
are coated
to
protect
against
external
corrosion
when in contact
with
masonry,
plaster,
or
insulation,
or
subjected
to
repeated
wetting
by liquids
such as water
(except
rain
water),
detergents,
or sewage.
Location of Manual VaIve
(InstaIled Ahead of
?
t
Ground Joint Pipe Union)
Height Required
By Local Code
Ground Joint Pipe Union
To Be installed Ahead of
n\
Gas Valve
Drip Leg
-'.
Reducing Coupling
_
1/2" x 1/8" with 1/8"
Pipe Plug To Measure
Line Gas Pressure
General
Furnace
Layout
UPFLOW INSTALLATIONS
When
the gas piping
enters
through
the right
side of the furnace,
the installer
must
supply
the following
fittings
(starting
from
the
gas valve):
• 90 degree
elbows
(2).
• Close
nipple.
• Straight
pipe to reach
the exterior
of the furnace.
A ground
joint union,
drip leg, and manual
shutoff
valve
must
also
be supplied
by the installer,
in some
cases,
the installer
may also
need
to supply
a transition
piece from
1/2" to another
pipe size.
When
the gas
piping
enters
through
the left side of the furnace,
the installer
must
supply
the following
fittings
(starting
from
the
gas valve):
• Straight
pipe to reach
the exterior
of the furnace.
• A ground
joint
union,
drip
leg, and
manual
shutoff
valve
must
also be supplied
by the installer.
In some
cases,
the
installer
may also need to supply
a transition
piece from
1/
2 inch to another
pipe size.
COUNTERFLOW INSTALLATIONS
When
the gas piping
enters
through
the left side of the furnace,
the installer
must supply
a straight
pipe to reach
the exterior
of the
furnace.
A ground
joint
union,
drip leg, and manual
shutoff
valve
must also
be supplied
by the installer,
in some
cases,
the installer
may also
need
to supply
a transition
piece
from
1/2" to another
pipe
size.
When
the gas piping
enters
through
the right
side of the furnace,
the installer
must
supply
the following
fittings
(starting
at the gas
valve):
• 90 degree
elbow.
• Close
nipple.
• 90 degree
elbow.
• Straight
pipe to reach
exterior
of furnace.
GAS PIPING
CHECKS
Before
placing
unit
in operation,
leak
test
the
unit
and
gas
connections,
,_
WARNING
I
TO
AVOID
THE
POSSIBILITY
OF EXPLOSION
OR
FIRE, NEVER
USE A MATCH
OR
OPEN
FLAME
TO TEST
FOR LEAKS.
Check
for leaks
using
an approved
chloride-free
soap
and water
solution,
an electronic
combustible
gas detector,
or other approved
testing
methods.
_kCAUTION
To
PREVENT
PROPERTY
DAMAGE
OR
PERSONAL
INJURY
DUE
TO FIRE, THE
FOLLOWING
INSTRUCTIONS
MUST
BE PERFORMED
REGARDING
GAS
CONNECTIONS,
PRESSURE
TESTING,
LOCATION
OF SHUTOFF
VALVE
AND
INSTALLATION
OF GAS
PiPiNG.
NOTE:
Never
exceed
specified
pressures
for testing.
Higher
pressure
may
damage
the
gas
valve
and
cause
subsequent
overfiring,
resulting
in heat exchanger
failure.
Disconnect
this unit and shutoff
valve
from the gas supply
piping
system
before
pressure
testing
the
supply
piping
system
with
pressures
in excess
of 1/2 psig (3.48
kPa).
This
unit must be isolated
from the gas supply
system
by closing
its manual
shutoff
valve
before
pressure
testing
of gas
supply
piping
system
with
test pressures
equal
to or less than
1/2 psig
(3.48 kPa).
PROPANE GAS TANKS AND PIPING
_II,
WARNIN G
IF THE GAS FURNACE
IS INSTALLED
IN A BASEMENT,
AN EXCAVATED
AREA
OR A CONFINED
SPACE,
IT IS STRONGLY
RECOMMENDEDTO
CONTACT
A PROPANE
SUPPLIER
TO INSTALL
A GAB DETECTING
WARNING
DEVICE
IN CASE
OF A GAB LEAK.
• SINCE
PROPANE
GAS IS HEAVIER
THAN
AIR, ANY
LEAKING
GAS CAN
SETTLE
IN ANY
LOW
AREAS
OR CONFINED
SPACES.
• PROPANE
GAS ODORANT
MAY FADE,
MAKING
THE GAS UNDETECTABLE
EXCEPT
WITH A WARNING
DEVICE.
19