Circulator Blower Speed Adjustment; Circulator Blower Fan Timing Adjustment; Operational Checks; Burner Flame - Goodman GMH8 Installation Instructions Manual

Gas-fired warm air furnace
Table of Contents

Advertisement

CIRCULATOR
BLOWER SPEED ADJUSTMENT
I_WARNING
To
AVOID PERSONAL INJURY OR DEATHDUETO ELECTRICAL SHOCK,TURN
OFF POWERTO THE FURNACEBEFORECHANGINGSPEEDTAPS,
This furnace
is equipped
with a PSC circulator
blower
motor.
This
blower
provides
ease
in adjusting
blower
speeds.
The
Product
Data
Book
applicable
to your
model
provides
an airflow
table
showing
the relationship
between
airflow
(CFM)
and external
static
pressure
(E.S.P.)
and a table
for the proper
selection
of heating
and cooling
speeds.
The cooling
blower
speed
is shipped
set on
HIGH.
High
heat
ships
on MEDIUM
and low heat
is shipped
on
MEDIUM-LO.
These
blower
speeds
should
be adjusted
by the
installer
to match
the installation
requirements
so as to provide
the correct
heating
temperature
rise and the correct
cooling
CFM.
To adjust
the circulator
blower
speed,
proceed
as follows:
1.
Turn
OFF power
to the furnace.
2.
Select
the heating
and cooling
blower
speeds
that match
the installation
requirements
from
the airflow
table
in the
Product
Data
Book
applicable
to your
model.(Please
contact
your
distributor
or our website
for the applicable
product
data
book
referred
to in this manual.)
3.
Relocate
desired
motor
leads
to the circulator
blower
heat
and cool speed
terminals
on the integrated
control
module.
(Terminals
are identified
as LO HEAT, HI HEAT and COOL
(hot)).
If a heating
speed
and the cooling
speed
are the
same,
a jumper
wire
must
be used
between
the heat
and
cool
terminals.
4.
Connect
all unused
blower
motor
leads
to the
"PARK"
terminals
on the integrated
control
module.
Any
leads not
connected
to the "PARK"
terminals
must
be taped.
5.
Turn
ON power
to furnace.
6.
Verify
proper
temperature
rise as outlined
in Temperature
Rise
section.
CIRCULATOR
BLOWER
FAN TIMING ADJUSTMENT
NOTE:
Items in this section
refer to the air circulator
blower
fan,
NOT to the induced
draft
blower.
The induced
draft blower
timing
sequence
is not adjustable.
The
circulator
blower
fan timing
is
adjustable
only on models
with
optional
"heatinq
fan OFF
delay"
adjustment
pins or switches.
It is NOT
adjustable
in any
other
circumstances.
As shipped,
the
circulator
blower
fan will
remain
on for
150
seconds
after the gas valve closes.
When a call for cooling
occurs,
the circulator
fan comes
on and remains
on for 45 seconds
after
the call for cooling
ends.
During
normal
heating
operation,
the
circulator
fan will come
on approximately
34 seconds
after
the
gas valve
opens.
150
100
_
SECOND
SECOND
O .AY
O 'AY
Switch
viewed
in an upflow
installation.
Adjustment
Switch
XlII. OPERATIONAL CHECKS
,_
WARNING
To
AVOID
PERSONAL
INJURY
OR DEATH,
DO NOT
REMOVE
ANY
INTERNAL
COMPARTMENT
COVERS
OR ATTEMPT
ANY
ADJUSTMENT.
ELECTRICAL
COMPONENTS
ARE
CONTAINED
IN BOTH
COMPARTMENTS.
CONTACT
A
QUALIFIED
SERVICE
AGENT
AT ONCE
IF AN ABNORMAL
FLAME
APPEARANCE
SHOULD
DEVELOP.
BURNER
FLAME
The
burner
flames
should
be
inspected
with
the
burner
compartment
door
installed.
Flames
should
be stable,
quiet,
soft,
and blue
(dust
may
cause
orange
tips but they
must
not be
yellow).
Flames
should
extend
directly
outward
from the burners
without
curling,
floating,
or lifting
off.
Flames
must not impinge
on
the sides
of the heat
exchanger
firing
tubes.
Check
the
burner
flames
for:
1
Good
adjustment
2
Stable,
soft
and
blue
3 Not
curling,
floating,
or lifting
off
Burner Flame
AUXILIARY
LIMIT CONTROL
Auto
reset
limits are located
on or near the blower.
To access
this
auxiliary
limit,
disconnect
the electrical
power
and
remove
the
blower
door.
The
auxiliary
limit
control
is designed
to prevent
furnace
operation
in case
of main
blower
failure
on horizontal
installations.
It may also
open
if the power
supply
is interrupted
while
the furnace
is firing.
The auxiliary
limit control
is suitable
for
both
horizontal
right
and horizontal
left
installations.
Regardless
of airflow
direction,
it does
not need
to be relocated.
,_WARNING
To
AVOID
PERSONAL
INJURY
OR DEATH,
DO NOT
REMOVE
ANY
INTERNAL
COMPARTMENT
COVERS
OR ATTEMPT
ANY
ADJUSTMENT.
ELECTRICAL
COMPONENTS
ARE
CONTAINED
IN BOTH
COMPARTMENTS.
CONTACT
A
QUALIFIED
SERVICE
AGENT
AT ONCE
IF AN ABNORMAL
FLAME
APPEARANCE
PREVENT
PROPERTY
DAMAGE,
PERSONAL
INJURY
OR DEATH
DUE
TO FIRE,
25