Gas Supply Pressure Measurement; As Anifold Ressure Easurement And Gas Input Rate Measurement; Adjustment - Goodman GMSS96 Installation Instructions Manual

Table of Contents

Advertisement

G
S
P
M
AS
UPPLY
RESSURE
EASUREMENT
G
P
T
AS
RESSURE
EST
The line pressure supplied to the gas valve must be within the range specified below. The supply pressure can be measured at the gas
valve inlet pressure tap or at a hose fitting installed in the gas piping drip leg. The supply pressure must be measured with the burners
operating. To measure the gas supply pressure, use the following procedure.
Gas Valve ON/OFF Selector Switch
OUTLET
Regulator
Outlet Pressure
Cover Screw
White-Rodgers Model 36J22
Figure 40A
1. Turn OFF gas to furnace at the manual gas shutoff valve
external to the furnace.
2. Connect a calibrated water manometer (or appropriate gas
pressure gauge) at either the gas valve inlet pressure tap or
the gas piping drip leg. See White-Rodgers 36J22 gas valve
figure for location of inlet pressure tap.
NOTE: If measuring gas pressure at the drip leg, a field-supplied hose barb fitting must be installed prior to making the hose
connection. If using the inlet pressure tap on the White-Rodgers 36J22 gas valve, then use the 36G/J Valve Pressure Check Kit, Part
No. 0151K00000S.
3. Turn ON the gas supply and operate the furnace and all other gas consuming
appliances on the same gas supply line.
4. Measure furnace gas supply pressure with burners firing. Supply pressure
must be within the range specified in the Inlet Gas Supply Pressure table.
If supply pressure differs from table, make the necessary adjustments to pres-
sure regulator, gas piping size, etc., and/or consult with local gas utility.
5. Turn OFF gas to furnace at the manual shutoff valve and disconnect manometer. Reinstall plug before turning on gas to
furnace.
6. Turn OFF any unnecessary gas appliances stated in step 3.
G
M
P
M
AS
ANIFOLD
RESSURE
Only small variations in gas pressure should be made by adjusting the gas valve
pressure regulator. The manifold pressure must be measured with the burners
operating. To measure and adjust the manifold pressure, use the following proce-
dure.
Inlet Pressure
A
EASUREMENT AND
DJUSTMENT
INLET
OUTLET
Natural
Propane
34
White-Rodgers Model 36J22
Connected to Manometer
Figure 40B
Manifold Gas Pressure
Gas
Range
3.2 - 3.8" w.c.
9.7 - 10.3" w.c.
Gas Line
Gas
Shutoff
Valve
Gas Line
To Furnace
Open To
Atmosphere
Drip Leg Cap
With Fitting
Manometer Hose
Manometer
Measuring Inlet Gas Pressure (Alt. Method)
Figure 41
INLET
Nominal
3.5" w.c.
10.0" w.c.

Hide quick links: