Check1; Proper Chimney Termination; Chimney Crown Condition - Goodman GMH8 Installation Instructions Manual

Gas-fired warm air furnace
Table of Contents

Advertisement

Proper Chimney
Termination?
(Check1)
Chimneychannel
free of solidand
liquid
fuel
appliances?
Crownin
good
ileal
condition
(Check
3)
Cleanout
free of
debris?
(Check 4)
Liner in good
_\1
condition?
(Check
5)
Dilutionair
_
available?
(Check
6)
Complete the
installation
(Check
7)
_
Line, terminate
with
listed
vent cap
(Fix 1)
Change
venting
arrangements
(Fix 2)
Rebuild crown
(Fix 3)
and/or Reline
(Fix 4)
Reline
(Fix 4)
Reline
(Fix 4)
Reline
(Fix 4)
CHECK 1
- PROPER
CHIMNEY TERMINATION.
A masonry
chimney
used
as a vent for gas fired
equipment
must
extend
at least three
feet above
the highest
point where
it passes
through
the roof. It must extend
at least two feet higher
than
any
portion
of a building
within
a horizontal
distance
of 10 feet.
In
addition,
the chimney
must
terminate
at least
3 feet
above
any
forced
air inlet located
within
10 feet.
The chimney
must extend
at
least five feet above
the highest
connected
equipment
draft hood
outlet
or flue collar.
If the chimney
does not meet
these
termination
requirements,
but
all other
requirements
in the checklist
can
be met,
it may
be
possible
for a mason
to extend
the chimney.
If this will
not be
practical,
see Fix 1.
[
,_.d !°'°''-e=" ',
=M in
Parapet
Chimney ?
Chimney
Termination
10 Feet Or Less From Ridge, Wall
or Parapet
More Than 10' _
NT
3'
in.
NOTE: No height above m= a:
i!
il _
parapet required when
Wall or
distance from wails or
himney
Parapet
parapet is more than 10
feet
More than 10'_rlH_!e_rfahabo_riz:W!:nah!_"
R
....
Iiil
Chimney
_ _%
Termination
More Than 10 Feet From Ridge, Wall or Parapet
CHECK2
- ANY SOLID OR LIQUID FUEL APPLIANCES VENTED INTO
THIS CHIMNEY CHANNEL
Solid
fuel
appliances
include
fireplaces,
wood
stoves,
coal
furnaces,
and
incinerators.
Liquid
fuel
appliances
include
oil furnaces,
oil-fired
boilers
and
oil-fired
water
heaters.
Appliances
which
burn propane
(sometimes
referred
to as LP
(liquefied
petroleum))
gas are considered
gas-fired
appliances.
CHECK3
- CHIMNEY
CROWN
CONDITION.
Damage
from
condensate
usually
shows
up first
in the crown.
If
any of the following
trouble
signs are present,
the condition
of the
crown
is not satisfactory:
12