Christie CP4220 User Manual page 169

Hide thumbs Also See for CP4220:
Table of Contents

Advertisement

Shutter/Douser (SHU)
Open/Close shutter/douser
SUBCODE
DESCRIPTION OF USE
Select douser position 0 - douser removed from optical path 1 - douser blocking optical path
NONE
The number of steps the douser should be moved when opening/closing (default 60, minimum 30, maxi-
STEP
mum 200)
EXAMPLES:
(SHU 1) Close shutter
(SHU 0) Open shutter
(SHU?) Get current status of shutter
(SHU+STEP?) Get number of steps douser should move to open/close
Select Input (SIN)
Selecting input port will reset the list and default data of DTF control. Use index number or text description to
select input port. Available options are:
"Auto-select",
"292-A",
"292-B",
"292-Dual",
"DVI-A",
"DVI-B",
"DVI-Dual/Twin"
SUBCODE
DESCRIPTION OF USE
Replace xxx with the channel number. Valid range is 101 - 164.
Cxxx
Select input for current channel
NONE
EXAMPLES:
(SIN?) Get current input port
(SIN?L) Show entries on the list
(SIN 1) Set current input port to entry with index 1
(SIN+C101 ?) Get input port on channel 101
(SIN+C101 1) Set input on channel 101
SNMP Agent Configuration (SNM)
This control will set the various configuration options for SNMP Agent
SUBCODE
DESCRIPTION OF USE
Enables/Disables SNMP version 2 and enables version 3
ENVT
Gets/sets the Lamp Expire Trap Flag for the SNMP Agent
LEXT
CP4220 User Manual
020-100690-02 Rev. 1 (01-2012)
Appendix B: Serial API
B-21