Normal Scrubbing; To Begin Scrubbing - Windsor chariot iscrub 20 CS20 Operating Instructions Manual

Hide thumbs Also See for chariot iscrub 20 CS20:
Table of Contents

Advertisement

3. Measure the chemical into the solution tank. Liquid
chemicals should be added to the solution tank
after filling with water. Dry chemicals should be
thoroughly mixed before being added into solution
tank. Commercially available, high alkaline floor
cleaners, are suitable for use in the solution sys-
tem.

Normal Scrubbing

Plan the scrubbing pattern in advance. The longest
track is around the perimeter of the area to be cleaned.
For efficient operation, the runs should be the longest
possible without turning, stopping, or raising or
lowering scrub deck/squeegee.
In order to achieve the best possible results, the area
which is to be cleaned should be swept before scrub-
bing. Large debris, strings and wire must be removed to
prevent being caught in brushes or squeegee.
If the machine is allowed to stand in neutral with the
scrub deck down, the solutions flow stops and brush
motor stops. If either forward or reverse travel is
selected, the solution flow will continue in the same
setting and the scrub brush motor will continue once
movement of machine begins. Overlap the brush path
and avoid transporting over previously cleaned areas.

To Begin Scrubbing

When operating the machine around people, pay
close attention for unexpected movement. Use
extra caution around children.
Lorsque vous utilisez la machine en présence de
gens, portez une attention particulière aux mouve-
ments inattendus. Soyez plus prudent, surtout en
présence d'enfants.
Flammable liquids and/or reactive metals can
cause explosions or fire! Do not pick up.
Les liquides inflammables et / ou les métaux
réactifs peuvent provoquer des explosions ou un
incendie ! Ne les ramassez pas.
1. Stand on the operator platform. Throttle pedal must
be in neutral position.
2. Turn machine power on.
3. Press the Drive Reset / Directional Control Switch,
selecting the desired travel direction.
4. Position the function control knob to the desired
operation. The scrub deck and squeegee will
lower, and the vacuum will turn on.
5. Drive machine forward to begin scrubbing.The
scrub brush motor will run and solution will flow
when the throttle is depressed.
NOTE: Shut machine off immediately if water or foam
is expelled from the machine. Solution flow is
automatically shut off when brush motor stops. When
brush motor is activated, flow automatically resumes.
86333220 CS20
Operations
23

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents