(4) Firmware Environment Commands

The printer maintains a number of printing parameters in its memory. There parameters may be changed per-
manently with the FRPO (Firmware RePrOgram) commands.
This section provides information on how to use the FRPO command and its parameters using examples.
Using FRPO Commands for Reprogramming Firmware
The current settings of the FRPO parameters are listed as optional values on the service status page.
Note: Before changing any FRPO parameter, print out a service status page, so you will know the parameter
values before the changes are made. To return FRPO parameters to their factory default values, send the
FRPO INIT (FRPO-INITialize) command.(!R! FRPO INIT; EXIT;)
The FRPO command is sent to the printer in the following sequence:
!R! FRPO parameter, value; EXIT;
Example: Changing emulation mode to PC-PR201/65A
!R! FRPO P1, 11; EXIT;
FRPO Parameters
Environment
Top margin
Left margin
Page length
Page width
Default pattern resolution
Copy count
Page orientation
Default font No. *
PCL font switch
Total host buffer size
Form feed time-out value
KIR mode
Para
meter
A1
Integer value in inches
A2
Fraction value in 1/100 inches
A3
Integer value in inches
A4
Fraction value in 1/100 inches
A5
Integer value in inches
A6
Fraction value in 1/100 inches
A7
Integer value in inches
A8
Fraction value in 1/100 inches
B8
0: 300 dpi
1: 600 dpi
C0
Number of copies to print:1-999
C1
0: Portrait
1: Landscape
C2
Middle two digits of power-up font
C3
Last two digits of power-up font
C5
First two digits of power-up font
C8
0:HP compatibility mode (Characters higher
than 127 are not printed.)
32:Conventional mode (Characters higher than
127 are printed. Supported symbol sets: ISO-60
Norway [00D], ISO-15 Italian [00I], ISO-11 Swe-
den [00S], ISO-6 ASCII [00U], ISO-4 U.K.
[01E], ISO-69 France [01F], ISO-21 Germany
[01G], ISO-17 Spain [02S], Symbol [19M]
H8
0 to 99 in units of the size defined by FRPO S5
H9
Value in units of 5 seconds (0 to 99).
N0
0: Off
2: On
2-4-5
2MH/2MJ/2MK/2ML
Values
)
a
Factory
setting
0
0
0
0
13
61
13
61
0
1
0
0
0
0
0
5
6
2