Download Print this page

Power Wiring - Linkcom Link IP iDP Quick User Manual

V1

Advertisement

3.1. Power Wiring

The Link IP iDP can be supplied in 2 different ways :
PoE (802.3at Class 3)
External power supply 12V DC
3.2. Relais : Mode and wiring
The relay has two different mode depending on the configuration « JP1 » jumper (see description of components):
« 12V Output » mode (default setting): At rest, the doorphone sends 12V to the "NC" and "COM" relay
terminals. When opening the door, the doorphone sends 12V between "NO" and "COM" relay terminals.
Jumper "JP1" must be placed between 2 and 3 terminals :
The maximum consumption supported is 12V / 500mA.
Wirind in « 12V Output » mode :
« Relay» mode : At rest, the "NC" and "COM" relay terminals are short-circuited. When opening the door,
the "NO" and "COM" terminals are short-circuited.
The 2 jumpers are positioned between terminals 1 and 2, then 3 and 4. (default):
Wiring in « Relais » mode :
p.6$|$9$
JP1
The 2 jumpers are placed
1
2
3
JP1
« Relais » mode, only one
jumper is placed on 2 and
3
1
2
3
4
4