5800 Series Transmitter Loop Numbers Diagram - Honeywell Lynx Touch L5200 Programming Manual

All-in-one home and business control system and alarm control panel
Hide thumbs Also See for Lynx Touch L5200:
Table of Contents

Advertisement

LOOP
1
LOOP
1
5 8 0 0 C O
5 8 0 0 M i c r a
E N R O L L A S " R F "
E N R O L L A S " R F "
LOOP
1
LOOP
5 8 0 0 WAV E
5 8 0 0 S S 1
P RO G R A M
E N RO L L A S " R F "
H O U S E I D
LOOP 1
5814
5 8 1 6
ENROLL AS "RF"
ENROLL AS "RF"
LOOPS
LOOP 3
1 - 3
5 8 2 1
5 8 2 2 T
ENROLL AS "RF"
ENROLL AS "RF"
LOOP 1
(HIGH
SECURITY)
LOOP 2
(STANDARD
SECURITY)
LOOP 3 (TILT MODE)
LOOP 4 (TAMPER)
5870API
ENROLL AS "RF"
Notes: (1) The 5806W3 smoke detector must be used in SIA applications.
(2) Button type (BR) devices send only fault and low battery signals; no restore or check-in signals.
Supervised RF (RF) devices send periodic check-in signals, faults, restore and low battery signals.
Unsupervised RF (UR) devices send periodic check-in signals, faults, restore and low battery signals but the
control does not supervise the check-in signals.
(3) If an external sounder is required, the 5800WAVE should be used.
(4) The 5804E and 5834-4 encrypted (High-Security) devices must be activated while the system is in Go/No-Go
Test Mode. Refer to the transmitter's Installation Instruction for complete details. The system will confirm the
enrollment of the encrypted device by beeping two times
(5) The 5800PIR-OD, 5800RL, 5800SS1, 5804E, 5804BD, 5804BDV, 5814, 5816TEMP, 5821, 5822T and
5828/5828V, 5877, 5878 wireless transmitters have not been evaluated by UL/ETL
UL
The 5800RL, 5802MN, 5802MN2, 5804, 5804BD, 5804BDV, 5814, 5816TEMP, 5819, 5819S(WHS & BRS), and
5828/5828V wireless transmitters
5800 Series Transmitter Loop Numbers
LOOP 1
5 8 0 0 P I R - R E S
E N R O L L A S " R F "
LOOP 3
O N
LOOP 4
LOOP 2
O F
F
LOOP 1
1
5804E
ENROLL AS "BR"
LOOP 2
LOOP 2
(REED)
(REED)
LOOP 1
LOOP 1
(TERMINALS)
(TERMINALS)
ALTERNATE
POSITION
FOR LOOP 2
5 8 1 6 M N
ENROLL AS "RF"
SERIAL #1
LOOP 3
A R
M E
D
R E
A D
Y
M IC
M ES
SA G
E
5 8 2 8 / 5 8 2 8 V
P RO G R A M
HOUSE ID
SERIAL #1
LOOP 3
SERIAL #1
LOOP 4
SERIAL #2
LOOP 3
5 8 7 7
ENROLL AS "BR"
have not been evaluated by UL
LOOP 1
(LOW
SENSITIVITY
LOOP 2
(HIGH
SENSITIVITY)
LOOP 3 (TEMP)
LOOP 4 (TAMPER)
5 8 0 0 P I R / 5 8 0 0 P I R - C O M
E N R O L L A S " R F "
LOOP 2
LOOP 4
LOOP
LOOP 1
3
• •
•• •
• • ••
• •
5 8 0 4 B D / 5 8 0 4 B DV
5806/5806W3/5807
ENROLL AS "BR"
5808/5808LST/5808W3
PROGRAM HOUSE ID
ENROLL AS "RF"
LOOP 2
(REED)
LOOP 3
LOOP 1
(TERMINALS)
LOOP 1
(TERMINALS)
5 8 1 8 M N L
ENROLL AS "RF"
ENROLL AS "RF"
SERIAL #2
LOOP 1
SERIAL #1
LOOP 2
SERIAL #2
LOOP 3
SERIAL #1
LOOP 4
SERIAL #2
LOOP 2
5834-2
ENROLL AS "BR"
ENROLL AS "BR"
SERIAL #1
A W
A Y
LOOP 2
S T
A Y
1
2
SERIAL #1
3
LOOP 1
4
SERIAL #2
LOOP 2
5 8 7 8
5 8 9 8
ENROLL AS "RF"
.
- 23 -
LOOP 1
(LOW
SENSITIVITY
LOOP 2
(HIGH
SENSITIVITY)
LOOP 3 (TEMP)
LOOP 4 (TAMPER)
5 8 0 0 P I R - O D
E N R O L L A S " R F "
LOOP 1
LOOP 1
5809
ENROLL AS "RF"
LOOP 2
(REED)
LOOP 3
(TERMINALS)
LOOP 1
(INTERNAL
SHOCK
SENSOR
5 8 1 9
5 8 1 9 S ( W H S & B R S )
ENROLL AS "RF"
SERIAL #2
LOOP 1
LOOP 1
SERIAL #2
LOOP 4
SERIAL #1
LOOP 1
5834-4
5 8 5 3
ENROLL AS "RF"
LOOP 1
(LOW SENSITIVITY)
LOOP 2
(HIGH SENSITIVITY)
5 8 0 0 R L
S E T H O U S E I D
LOOP 1
5 8 1 1
E N R O L L A S " R F "
LOOP 1
5 8 2 0 L
ENROLL AS "RF"
5869
ENROLL AS "RF"

Advertisement