Mains Power Supply - ESAB ESABMig 405 Instruction Manual

Hide thumbs Also See for ESABMig 405:
Table of Contents

Advertisement

GB
5.5

Mains power supply

Check that the unit is connected to the correct mains power supply voltage, and that it is protected by
the correct fuse size. A protective earth connection must be made, in accordance with regulations.
ESABMig 405
Voltage V
Current A
at100% duty cycle
at 60% duty cycle
at 50% duty cycle
2
Cable area mm
Fuse, slow A
ESABMig 505
Voltage V
Current A
at100% duty cycle
at 60% duty cycle
2
Cable area mm
Fuse, slow A
NB: The mains cable areas and fuse sizes as shown above are in accordance with Swedish
regulations. They may not be applicable in other countries: make sure that the cable area and fuse
sizes comply with the relevant national regulations.
405,505e
Rating plate with supply connection data
3∼ 50 Hz
3∼ 50/60 Hz
230
400/415
28
16
42
24
45
28
4 x 6
4 x 2,5
25
20
3∼ 50 Hz
3∼ 50/60 Hz
230
400/415
43
25
68
39
4 x 16
4 x 6
63
35
– 63 –
3∼ 50 Hz
3∼ 60 Hz
500
230
13
28
19
41
20
45
4 x 2,5
4 x 6
20
25
3∼ 50 Hz
3∼ 60 Hz
500
230
20
43
31
68
4 x 6
4 x 16
35
63
3∼ 60 Hz
440/460
14
21
22
4 x 2,5
20
3∼ 60 Hz
440/460
23
35
4 x 6
25

Hide quick links: