Back Panel Removal; Cooling Blower Motor Removal - Viking VDSC530 Service Manual

Hide thumbs Also See for VDSC530:
Table of Contents

Advertisement

To avoid risk of electrical shock, personal injury, or death, disconnect electrical power source to unit, unless test
procedures require power to be connected. Discharge capacitor through a resistor before attempting to service.
Ensure all ground wires are connected before certifying unit as repaired and/or operational.
3. Remove two screws and hinge receiver from range.
4. Reverse procedure for installation.

Back Panel Removal

Condition Requirements:
Island Trim or Backguard Assembly Removed
1. Remove two screws and access door from back
cover.
2. Remove three screws and rear wiring channel from
range.
3. Remove 12 screws and back panel from range.
©2009 Viking Preferred Service
4. Remove two screws and fl ue from air duct.
5. Remove four screws and air duct from range.
6. Reverse procedure for installation.

Cooling Blower Motor Removal

Condition Requirements:
Back Panel Removed
1. Remove three screws from blower motor.
2. Remove four screws and blower mount from range.
3. Mark and disconnect three connectors and remove
blower motor.
4. Reverse procedure for installation.
Disassembly
45

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Vdsc536Vdsc548

Table of Contents