Hardware Monitor - Sans Digital Mobileraid MR8X Detailed User's Manual

Table of Contents

Advertisement

SAS-to-SATA II RAID Subsystem

4.6.3 Hardware Monitor

To view the RAID subsystem's hardware information, click the Hardware Monitor link from
the Information menu. The Hardware Monitor Information screen appears.
NOTE: When no disk drive is installed in the disk slot, the disk
temperature will show "--". The disk temperature will also show "--"
when "HDD SMART Status Polling" is disabled in System
Configuration.
The Hardware Monitor Information provides the temperature and voltage levels of the RAID
subsystem. All items are also unchangeable. When the threshold values are surpassed,
warning messages will be indicated through the LCD, LED and alarm buzzer.
Item
Controller Board Temperature
HDD Temperature
Power Supply +12V
Power Supply +5V
Power Supply +3.3V
DDR Supply Voltage +2.5V
CPU Core Voltage +1.3V
DDR Termination Power +1.25V
73
Installation and Configuration Manual
Warning Condition
> 60 Celsius
> 55 Celsius
< 10.5V or > 13.5V
< 4.7V or > 5.4V
< 3.0V or > 3.6V
< 2.25V or > 2.75V
< 1.17V or > 1.43V
< 1.125V or > 1.375V