1.36

FAULT FINDING

PROBLEM
Engine will not turn over
Engine smokes
Engine runs then stops
FAULT FINDING
POSSIBLE FAULT
Engine stop lever released
Incorrect oil level
Obstruction under deck
Battery discharged
(electric start models)
Excess oil level
Air cleaner cartridge oil
soaked or plugged
Fuel starvation
Fuel cap vent blocked
REMEDY
Operate engine stop lever
Check oil level
Remove obstruction
Charge battery
Check oil level
Service air cleaner
Fill fuel tank
Clean fuel cap vent