Standard Equipment; Optional Equipment - gledhill BMA 200 SP-SOL Installation & Servicing Instructions Manual

Boilermate sp sol a-class
Hide thumbs Also See for BMA 200 SP-SOL:
Table of Contents

Advertisement

13
21
36
33
34
32
30
35
28
23
25
11
1
2
11
22
29
20
17
Note 1: All the panels, pipework and other components necessary for the installation
of the remainder of the solar system can be supplied by Gledhill with the BMA SP SOL
appliance. For further details please contact the Gledhill Technical Sales Dept.
Note 2: A single feed and expansion cistern will be supplied with the BMA 200 and 220
SP SOL appliances. Two feed and expansion cisterns will be supplied for other models.
Note 3: A solar commissioning/filling assembly is provided separately for fitting
vertically on site (see diagram on page 9 for more detail).

Standard Equipment

The standard configuration of the BoilerMate
14
A-Class SP SOL is shown opposite. The Appliance
Controllers mounted inside the appliance,
control the operation of the complete system.
These are pre-wired to a terminal strip where all
27
electrical connections terminate. It is supplied
with the following factory fitted equipment:-
1
2
3
4
26
5
6
7
8
9
3
10 Plate heat exchanger
11 Isolating valves
12 Non return valve
13 Open vent/safety connection
31
14 Cold feed/expansion connection
15 CW inlet connection
11
16 HW outlet connection
17 Thermal store drain tapping
18 Return from PHE to store
19 Flow from store to PHE
19
20 Combined boiler/heating return
4
21 Primary flow manual air vent
22 Boiler flow (from boiler)
11
23 CH flow
24 2 port valve V1 (boiler flow)
8
25 2 port valve V2 (CH flow)
5
26 Solar heat exchanger return connection
7
27 Solar heat exchanger flow (collector)
16
28 Remote solar panel sensor (T1) & cable
29 Solar return sensor (T2)
10
30 Solar overheat sensor (T3)
31 Solar circuit pump UPS 15-60 (high temp.)
24
32 Solar controller
6
33 User control panel/clock
18
34 Appliance control board
11/12
35 Electrical DIN rail
36 Solar expansion vessel connection (fitted
9
15
37 100mm high installation base
37

Optional Equipment

Figure 1.9
Page 9
DESIGN
Switch immersion heater (2 x 3kW elements & OHT' s )
Grundfos UPR 15-50 (185 & 215 model) or
15-60 boiler/central heating pump
Overheat (top) sensor pocket (Sensor S1/S2)
Middle sensor pocket (Sensor S6)
Bottom sensor pocket (Sensor S5)
DHW (CW) inlet sensor, S3
DHW outlet sensor, S4
Grundfos UPR 15-50 PHE pump
Filter & flow regulator
to solar panel
connection from panel
with pressure gauge)
Hot and cold water manifolds for use with
plastic pipework (Set 1 or 2).
Electronic scale inhibitor for mains water
services with hardness levels above
200ppm (mg/l) fitted in the appliance.
Polyphosphate scale and corrosion inhibitor
for mains water services with hardness
levels above 300ppm (mg/l) for fitting on
site by the installer.