DESIGN
Model Selection Data Table/Weights
Model Reference
Bedrooms
Dwelling
Bathrooms
type
En-Suite
(m 2 )
Max Floor Area
Empty
(kg)
Weight
Full
(kg)
Total
(l)
Volume
Solar
(l)
Note:
It is important that the maximum floor area is not exceeded to achieve compliance
with the SAP regulations.
BMA
BMA
BMA
BMA
200 SP
220 SP
240 SP
260 SP
SOL
SOL
SOL
SOL
2-3
2-4
3-5
3-5
1
2
2
2
2
1
2
3
80
100
130
170
73
79
96
104
233
260
313
366
160
181
217
262
82
93
109
127
gulley or else issue externally at ground level.
High level termination from walls or on roofs
BMA
BMA
could cause injury to people or animals below
280 SP
300 SP
if the valve were to release scalding water and
SOL
SOL
steam.
4-5
5-6
The pipe leading to the safety device and
2
3
the collector should be of rigid and non-
deformable construction, without any possibility
3
3
of restriction or disclosure by any other fitted
220
280
component.
112
120
In order to meet the Building Regulations
411
472
requirement to reduce the rate of accumulation
of scale in hard water areas, it is important
299
352
that the installer checks the hardness of the
148
167
incoming water supply.
If this exceeds 200ppm (mg/l), we recommend
that the factory fitted scale inhibitor is ordered
as an optional extra.
If it exceeds 300ppm (mg/l), we recommend the
use of a polyphosphate type of scale inhibitor.
This can also be ordered as an optional extra but
will need fitting on site by the installer.
Note:
If the summer towel rail circuit is required, this
will need to be a separate zoned circuit from the
heating circuit complete with its own time and
temperature controls.
The standard manual fill model BoilerMate A-
Class SP SOL appliance is shown. A ballvalve and
overflow are available as an optional extra at the
time of order. If required, these should be fitted
in the plain F&E cistern in a position to suit the
individual site conditions.