Function Test
The regulator is ready for operation when connected to the mains. The display
becomes active and current temperatures are shown. Display updates once per
minute. By pressing INFO button display updates immediately.
Regulator Fault Display
If the temperature sensors have a fault, this is shown by the red LED being lit and F1
or F2 flashing.
Call in the installer.
If the red LED is lit and the store temperature flashes at the same time, the temperature
of the hot water tank may be too high. If this state continues, call in the installer.

Temperature Indicator

Solar collector
°C
Display
Meaning
F1 flashes
Sensor fault / alarm
200
150 °C flashes
High temp.
150
Temp. flashes
120

Operating range

0
Temp. flashes
-9
Low temp.
- 9°C flashes
-40
F1 flashes
Sensor fault / alarm
Power failure
In case of power failure, the regulator remembers the accumulated solar heat output
and the day counter for 24 hours. The pump mode setting is also retained.
Trouble shooting
Display
Cause
No display
230V supply off
Red LED lit
Fault sensor 1 (collector)
Display flashes "F1"
Red LED lit
Fault at sensor 2 (tank)
Display flashes "F2"
Red LED lit
Pump does not run
Tank temp >95°
Pump cannot "keep up"
Pump runs, indicates high
No alarm,
temperature
temperature flashes
Pump does not run
For any further technical information/assistance regarding this product please ring
the Gledhill Technical helpline on 08449 310000.
Thermal Store
°C
Display
Meaning
F2 flashes
Sensor fault / alarm
120
99°C flashes
High temp./ alarm
99
Temp. flashes
95
Operating range
0
0°C flashes
Low temp.
-40
F2 flashes
Sensor fault / alarm
Remedy
Check supply/connections
Check connections/sensor
Check connections/sensor
Check pump model/
connections
Set speed higher
Set speed higher
Pump or pump output
defective
Page 15
INSTALLATION
Annual Servicing
No annual servicing of the BoilerMate A-Class
SP SOL appliance is necessary.
However, if required, the operation of the
controls and a hot water performance test can
be carried out when servicing the boiler to
prove the appliance is working satisfactorily
and within its specification.
At the same time, a check should be made of
the solar system pressure/expansion vessel
charge pressure along with a visual check of
the solar panels.
It is recommended that after five years, the
concentration/quality of the solar system
antifreeze solution is checked and, if necessary,
replaced.